background image

Document Created by: 

Sikich Graphic Design & Marketing Services

Document Creator Contact Information:

Sikich Graphic Design & Marketing Services
1300 Iroquois Ave., Suite 260
Naperville, IL 60563
p 630.717.7515
f 630.717.7150

Document Designer:

Rick Byers

Client

Aquascape, Inc.

Designer E-Mail:

[email protected]

Client Contact

Scott Rhodes

Icon Job Number:

11088796

Client Contact E-Mail

[email protected]

Number of Colors

1/1

Client P.O. Number

110141

Number of Pages

8

Client Job Description:

39000 Pond De-Icer 300-Watt Instructions 08-11

Flat Size

 (W x H)

17” x 11”

Folded Size

 (W x H x D)

8.5” x 11”

8

 

US 1-866-877-6637 | 

 

CAN 1-866-766-3426 | www.aquascapeinc.com

For more information about our company or products, please visit our website at www.aquascapeinc.com  

or call us at (US) 1-866-877-6637 (CAN) 1-866-766-3426

©2014 Aquascape, Inc. • All Worldwide Rights Reserved

•  

Winter Storage –

 If concerned about possible freeze 

damage, disconnect the tubing from the discharge fitting 
and remove the pump from the water. Clean the pump 
and inlet screens with fresh water and store the pump in 
a frost-free location. The pump can be run during cold 
weather, if desired, but should be removed in the event of 
a power failure to prevent any freeze damage to either the 
pump or the piping.

Troubleshooting

• 

Reduced Water Flow

 

 

 –  It may be necessary to clean the front  

cover, filter sponge and impeller.

•  

Pump Hums and Doesn’t Push Water

 

–   It may be necessary to clean the front cover,  

filter sponge and impeller.

 

–  Remove the water chamber cover and inspect  

and clean the impeller rotor assembly and  
internal pump body.

 

–   Make sure nothing is blocking  

or wrapped around the impeller.

 

– Make sure the pump is receiving the correct voltage.

•  

Pump Not Working

 

–  The ground-fault circuit-interrupter (GFCI)  

may have tripped

 

– The pump is not receiving the correct voltage.

91054.11276

1b.  A centering bushing is required on both ends of the 

impeller shaft; one bushing is located inside the pump 
and an outer bushing sits in the Water Chamber Cover.

2.  Slide the first interior bearing washer onto the ceramic shaft.
3.  Place the ceramic impeller shaft into the pump, checking 

to be sure the centering bushing seats inside the pump.

4.  Carefully slide the impeller back onto the shaft. Use 

caution: the Impeller Assembly is magnetic and will be 
forcefully pulled back into the pump.

5.  Install second outer bearing washer over the  

impeller shaft. 

6.  Replace Water Chamber Assembly, containing the 

impeller shaft centering bushing by sliding it over the 
impeller shaft and then rotating it clockwise to lock it  
into place over the tabs on the pump housing. 

7.  Replace the Pump Cover and Filter Sponge by snapping 

them back onto the pump housing.

2

1b

5

6

7

3

4

I N S T R U C T I O N S   E T   E N T R E T I E N

91054 - 91005, 91006, 91007, 91008, 91009, 91010 Ultra Pump Instructions D7.indd   8

10/3/14   3:12 PM

Содержание Signature series 400

Страница 1: ...mp For Models 400 Item 91005 550 Item 91006 800 Item 91007 1100 Item 91008 1500 Item 91009 2000 Item 91010 Available in flow rates from 400 to 2000 GPH I N S T R U C T I O N S M A I N T E N A N C E Ul...

Страница 2: ...efective No liability for loss or damage of any nature or kind whether arising out of or from the use of the product whether defective or not defective is assumed by Aquascape Inc or its affiliates Co...

Страница 3: ...r 8 1 1 Multi Hose Adapter 9 Barb Valve 1 Front Cover 2 Filter Sponge 3 Water Chamber Assembly 5 Impeller Assembly 5 Rubber Feet 6 Main Housing 7 Back Cover 8 x 1 1 Multi Hose Adapter 9 3 way Valve 10...

Страница 4: ...o lift pump Installation Always operate the pump fully submerged Failure to do so will overheat the pump and cause it to fail thus voiding the warranty DO NOT OPERATE DRY Use only in fully assembled s...

Страница 5: ...ative fountain container To maximize pond circulation locate the pump as far away as possible from the location of the water entering back into the water feature Pond with external filter Decorative F...

Страница 6: ...tected by a ground fault interrupter Once the pump is running and water is circulating through the filter s or waterfalls check for any fitting or waterfall leaks where the external connections are ma...

Страница 7: ...ler Kits are available through your local Aquascape dealer 1a Note the orientation of parts in the photo below The replacement impeller kits include all parts shown Make sure to remove all of the orig...

Страница 8: ...rotor assembly and internal pump body Make sure nothing is blocking or wrapped around the impeller Make sure the pump is receiving the correct voltage Pump Not Working The ground fault circuit interru...

Страница 9: ...no 91005 550 article no 91006 800 article no 91007 1100 article no 91008 1500 article no 91009 2000 article no 91010 Disponible en d bits de 1514 7570 L h Ultra MC 400 550 800 1100 Ultra MC 1500 2000...

Страница 10: ...uts dans les mat riaux et les d fauts de fabrication seulement Le remplacement de l unit d fectueuse par une unit de rechange appropri e sera la seule obligation Les unit s devront tre v rifi es afin...

Страница 11: ...usqu 86 36 cm Jusqu 55 88 cm Jusqu 218 44 cm UltraMC 2000 91046 Jusqu 91 44 cm Jusqu 60 96 cm Jusqu 243 84 cm Cloche d eau Jet moussant Fontaine marguerite Trousse de t tes de fontaines Mod le de pomp...

Страница 12: ...son utilisation sinon elle pourrait surchauffer entra nant ainsi sa d faillance et annulant de ce fait la garantie NE FAITES PAS FONCTIONNER LA POMPE SEC Utilisez seulement lorsque la pompe est enti r...

Страница 13: ...lan d eau ou une fontaine d corative La pompe UltraMC est con ue pour tre submerg e directement dans le plan d eau ou le r servoir de la fontaine d corative Pour maximiser la circulation d eau dans le...

Страница 14: ...filtration de la pompe Dans de nombreux cas la cage de filtration bouch e peut tre nettoy e en plongeant la main dans la pompe et en retirant manuellement les d bris de la cage de filtration S il y a...

Страница 15: ...ontre au del des indicateurs et en tirant pour le d loger Ceci exposera l assemblage de la turbine pour une meilleure inspection Enlevez soigneusement la turbine de la pompe tout en prenant garde de n...

Страница 16: ...uvercle du r servoir inspectez et nettoyez l assemblage du rotor de turbine et la partie interne de la pompe Assurez vous que rien ne bloque ou n est envelopp autour de la turbine Assurez vous que la...