background image

7

www.aquascapeinc.com | 

☎ 

CAN 1-866-766-3426 | 

☎ 

US 1-866-877-6637

•  The outer screen is designed to pop off when it is gently 

pulled from either side.

•  If your rotor assembly impeller and internal pump body 

have excessive scale build-up, clean with a mild acid, such 
as white vinegar or non-abrasive calcium, lime and rust 
remover product using a sponge or soft-bristled brush 
that won’t scratch. Removing scale build-up will allow your 
pump to run like new again. 

•  The pre-filter sponge is designed to protect the pump 

from fine particles, such as sand or other pond debris, that 
could clog or damage the interior of the pump. Clean the 
filter sponge using a bucket of pond water or rinse off with 
a garden hose. 

Replacing the Impeller

•  The impeller assembly is the only moving part on the 

Ultra

 Pump and will experience wear and tear. If 

you’ve cleaned the pump, as described above, and still 
experience poor pump performance, it is most likely time 
to replace the impeller. Replacing the impeller is extremely 
easy. Replacement Impeller Kits are available through your 
local Aquascape

®

 dealer.

1a.  Note the orientation of parts in the photo below.  

The replacement impeller kits include all parts shown.  
Make sure to remove all of the original parts from  
the inside of the pump before installing the replacement 
impeller kit.

•  

Internal Pump Cleaning –

 If you have thoroughly 

cleaned the filter screen and sponge on the pump and still 
have diminished flow rates, you will need to remove the 
water cover chamber by rotating it about ¼ turn counter 
clockwise past the tabs and pulling it off. This will expose 
the impeller assembly to allow for closer inspection. 
Carefully remove the impeller from the pump, being careful 
not to lose the two plastic bearing washers on either end 
of the impeller or the centering bushings that center the 
ceramic impeller shaft on both ends. 

1a

there is a lot of debris and/or the debris is difficult to clean, 
you may need to remove the pump from the pond or basin 
for a more thorough cleaning. A garden hose can be used 
to spray off any debris stuck on the filter screen or sponge. 
Be sure to replace both the screen and sponge and make 
sure they are firmly attached to the pump body, before 
lowering the pump back into the water.

91054 - 91005, 91006, 91007, 91008, 91009, 91010 Ultra Pump Instructions D7.indd   7

10/3/14   3:12 PM

Содержание Signature series 400

Страница 1: ...mp For Models 400 Item 91005 550 Item 91006 800 Item 91007 1100 Item 91008 1500 Item 91009 2000 Item 91010 Available in flow rates from 400 to 2000 GPH I N S T R U C T I O N S M A I N T E N A N C E Ul...

Страница 2: ...efective No liability for loss or damage of any nature or kind whether arising out of or from the use of the product whether defective or not defective is assumed by Aquascape Inc or its affiliates Co...

Страница 3: ...r 8 1 1 Multi Hose Adapter 9 Barb Valve 1 Front Cover 2 Filter Sponge 3 Water Chamber Assembly 5 Impeller Assembly 5 Rubber Feet 6 Main Housing 7 Back Cover 8 x 1 1 Multi Hose Adapter 9 3 way Valve 10...

Страница 4: ...o lift pump Installation Always operate the pump fully submerged Failure to do so will overheat the pump and cause it to fail thus voiding the warranty DO NOT OPERATE DRY Use only in fully assembled s...

Страница 5: ...ative fountain container To maximize pond circulation locate the pump as far away as possible from the location of the water entering back into the water feature Pond with external filter Decorative F...

Страница 6: ...tected by a ground fault interrupter Once the pump is running and water is circulating through the filter s or waterfalls check for any fitting or waterfall leaks where the external connections are ma...

Страница 7: ...ler Kits are available through your local Aquascape dealer 1a Note the orientation of parts in the photo below The replacement impeller kits include all parts shown Make sure to remove all of the orig...

Страница 8: ...rotor assembly and internal pump body Make sure nothing is blocking or wrapped around the impeller Make sure the pump is receiving the correct voltage Pump Not Working The ground fault circuit interru...

Страница 9: ...no 91005 550 article no 91006 800 article no 91007 1100 article no 91008 1500 article no 91009 2000 article no 91010 Disponible en d bits de 1514 7570 L h Ultra MC 400 550 800 1100 Ultra MC 1500 2000...

Страница 10: ...uts dans les mat riaux et les d fauts de fabrication seulement Le remplacement de l unit d fectueuse par une unit de rechange appropri e sera la seule obligation Les unit s devront tre v rifi es afin...

Страница 11: ...usqu 86 36 cm Jusqu 55 88 cm Jusqu 218 44 cm UltraMC 2000 91046 Jusqu 91 44 cm Jusqu 60 96 cm Jusqu 243 84 cm Cloche d eau Jet moussant Fontaine marguerite Trousse de t tes de fontaines Mod le de pomp...

Страница 12: ...son utilisation sinon elle pourrait surchauffer entra nant ainsi sa d faillance et annulant de ce fait la garantie NE FAITES PAS FONCTIONNER LA POMPE SEC Utilisez seulement lorsque la pompe est enti r...

Страница 13: ...lan d eau ou une fontaine d corative La pompe UltraMC est con ue pour tre submerg e directement dans le plan d eau ou le r servoir de la fontaine d corative Pour maximiser la circulation d eau dans le...

Страница 14: ...filtration de la pompe Dans de nombreux cas la cage de filtration bouch e peut tre nettoy e en plongeant la main dans la pompe et en retirant manuellement les d bris de la cage de filtration S il y a...

Страница 15: ...ontre au del des indicateurs et en tirant pour le d loger Ceci exposera l assemblage de la turbine pour une meilleure inspection Enlevez soigneusement la turbine de la pompe tout en prenant garde de n...

Страница 16: ...uvercle du r servoir inspectez et nettoyez l assemblage du rotor de turbine et la partie interne de la pompe Assurez vous que rien ne bloque ou n est envelopp autour de la turbine Assurez vous que la...

Отзывы: