32
Required components, tools and materials
For this work step, the following components, tools and materials are required:
Use of the electric fan PLUS with 5.2 Control Box or ISOBUS
Overview
No.
Designation
Meaning
1
Fan overload
control lamp
The LED lights up red if on of the motors is
strained at its limits for too long.
2
Fan not connected
control lamp
The LED lights up red if the cabling is faulty.
If only one fan is running, both connection lines
must be connected to this fan.
3
Fan status lamp
The LED lights up green when the voltage supply
is established.
Procedure
To use the motor module:
Step Description
1
The Control Box issues the
Error (fan)!
error message.
2
Check the display on the motor module.
3
Eliminate the respective fault according to Point 6.
6
FAULT INDICATIONS
In this section, you will find information for eliminating faults that may occur during operation.
6.1
FAULT OVERVIEW
Problem
Cause
Remedy
The seeding shaft does not
rotate when the drive shaft of the
gearbox motor is rotating.
The fitted key fell out of the drive
shaft.
Stick on a new fitted key.
The seed hoses get clogged
Fan speed too low.
Check the fan speed and increase
if necessary.
Control Box issues error
message
Error (fan)!
, control
lamp
E01
(
Fan overload
) lights
up red on the motor module.
One or both of the motors ran in
the limit range for too long.
Check or install the calibration
lid.
Check whether all of the
seeding hoses are installed.
Remove any foreign objects or
similar from the fan.
Check the fan for smooth
running.