20
Required components, tools and materials
For this work step, the following components, tools and materials are required:
Hexagon key
Torx screwdriver TX 30
Procedure
This is how you remove the swell air plate:
Step Description
Explanation
1
Loosen the hexagonal bolt (2) on the calibration
slide (1).
2
Remove the calibration slide.
3
Loosen the Torx screws (3) and remove the swell
air plate (4).
4.6
CONNECTING THE HYDRAULIC FAN (HF)
Purpose
The hydraulic fan is used for operation with working widths up to 12 m or for higher spread rates of e.g.
wheat.
Requirements
The following requirement must be fulfilled for this work step:
The hydraulic system is depressurized both on the tractor and implement side.
Required components, tools and materials
For this work step, the following components, tools and materials are required:
Coupling connector or coupling sleeve (for initial operation)
Overview
No.
Designation
1
Hydraulic block