21
No.
Designation
2
Flow control valve
3
Coupling sleeve (alternative)
4
Coupler plug
5
Return line
6
Pressure line
Procedure
This is how to connect the hydraulic fan:
Step Description
1
Completely close the flow control valve (2) on the hydraulic block (1).
2
Connect the return line (5) (marked in yellow, BG4) without reduction to the return flow
connection of the tractor hydraulic system.
For initial operation: Remove the plastic plug on the return line and connect the coupling plug
(4) or the coupling sleeve (3) with the return line.
3
Connect the pressure line (6) (marked in red, BG3) with a pressure connection of the tractor
hydraulic system.
4.7
CONNECTING THE ELECTRIC FAN PLUS
Purpose
The electric fan PLUS is used for operation with working widths up to 12 m or for higher spread rates of
e.g. wheat.
Requirements
The following requirements must be fulfilled for this work step:
Use of the electric fan PLUS with a 5.2 Control Box (hardware version: as of 14.2, software version:
as of 1.28) or an ISOBUS (hardware version: as of CC16WP, software version: as of V3.0.0).
The electrical supply is disconnected.
Required components, tools and materials
For this work step, the following components, tools and materials are required:
Tractor cable set, implement cable
Procedure
To connect the motor module of the electric fan PLUS:
Step
Description
Explanation
1
Install the tractor cable set (1) close to the rear
hydraulic connections using the holding plate.
2
Connect the red end of the cable (2) to the positive
terminal of the tractor battery.
3
Connect the black end of the cable (3) to the
negative terminal of the tractor battery.