22
Quality for Professionals
10.2 Regulation of the seed rate
Regulating the spread rate
:
•
The required settings can be found in the corresponding
setting chart.
•
Loosen the knurled nut and set the metering slider to the
required scale position.
Position 0: closed; Position 10: fully open.
•
Fix the knurled nut again.
10.3 Agitator
Since driving of the agitator with two dowel pins is generally
not necessary, the agitator was only equipped with one
agitator pin ex factory. If, however, you should require
stronger agitation (e.g. for grass etc.), the following must be
performed: The dowel pins supplied as a standard are
attached on the bottom agitator pin of the agitator and this
increases the efficacy of the agitator.
10.4 Spreading disc, lateral distribution, throwing vanes
The spreading disc must rotate counterclockwise. The
spreading plate has 2 throwing vanes that are positioned not
quite parallel to each other. They are only slightly adjustable,
since their arrangement and shape are already trimmed for
perfect lateral distribution. The spreading cone is only corrected
using the point of impact adjustment and the throwing vanes. To
achieve optimal lateral distribution for the selected working
width, you must then still adjust the setting of the throwing
vanes on the spreading plate. When doing so, be sure to
disconnect the power supply from the control box! To adjust the
throwing vanes, loosen them and turn the throwing vane to the required position. Then
tighten all of the bolts again!
There are marks directly on the spreading plate, which can be used to see the current
position of the throwing vanes:
Throwing vane I at Point 4
Throwing vane II at Point 4
Fig.: 10
Fig.: 11
Fig.: 12
Fig.: 13
Fig.: 9