CSP-SNv Capacitor Charging Unit Operation
Manual
CSP-CSPSNV-8000/3
_______________________________________________________________________________________________
__________________________________________________________________________________________________________
Page
37
of
56
Operation: Enable High Voltage with Remote Unit
•
CSP Local / Remote setting must be set to Remote.
•
CSP must be in OPERATION MODE.
•
HV must be off.
•
Fault modes must be reset.
Activation Sequence
1.
Hold Remote Unit HV OFF switch until HV ON switch flashes. This indicates the
operator has 5 seconds to enable HV.
2.
Release HV OFF switch.
3.
Hold HV ON switch for minimum of 3 seconds until HV ON activates.
Operation: Disable High Voltage with Remote Unit
Press HV OFF to switch OFF High Voltage
The chassis and control electronics of the Remote Unitl are isolated from
the CSP-SNv and can be connected to the local earth for safety.