CSP-SNv Capacitor Charging Unit Operation
Manual
CSP-CSPSNV-8000/3
_______________________________________________________________________________________________
__________________________________________________________________________________________________________
Page
29
of
56
Temperature
Description
Tca
Control Unit ambient temperature
Tco
Control Unit outlet temperature
Tout
Energy Unit outlet temperature
EOC Histogram
The histogram displays the status of the end of charge voltage history of the last 20
shots, this allows the operator to monitor the system operation at a glance with instant
feedback of the overall system performance.
The histogram is only reset upon HV ON, the display is retained upon shut down to
provide feedback.