CSP-SNv Capacitor Charging Unit Operation
Manual
CSP-CSPSNV-8000/3
_______________________________________________________________________________________________
__________________________________________________________________________________________________________
Page
11
of
56
EARTHING - FURTHER REMINDER
THIS UNIT MUST BE EARTHED / GROUNDED BEFORE ANY POWER IS APPLIED. FAILURE TO
DO SO MAY REPRESENT A SEVERE HAZARD TO BOTH EQUIPMENT AND PERSONNEL.
The front of the CSP-S
Nv must be grounded to the ship’s ground system. This is
achieved by attaching a short length of thick wire or earth braid from the CSP-SNv front
panel earth stud, to an appropriate earthing point on the vessel. If a suitable earth
cannot be found, the CSP-SNv earth stud should be connected directly to the water
using an adequate length of heavy wire, with the insulation removed from the
submerged end in the water. A weight will also be necessary to keep the wire
submerged when the vessel is underway.
The CSP-SNv range of Capacitor Discharge PSUs are compact and easy to operate.
However, the units still generate lethal voltages, and the operators should make
themselves aware of all necessary safety procedures. The equipment is designed so
that there is no need for the operator to go inside for anything, except major repairs.
We cannot be liable for any consequences should the units be opened. Health and
Safety guidelines and our own Safety Policy strongly suggest that factory training is
received before opening the top cover.