CSP-SNv Capacitor Charging Unit Operation
Manual
CSP-CSPSNV-8000/3
_______________________________________________________________________________________________
__________________________________________________________________________________________________________
Page
34
of
56
Operation: Enable High Voltage
To enable High Voltage press and hold the HV ON button for 3 seconds.
Depending on settings, 1,2,3,4 or 5 relays will engage over a fixed 6 second period.
High voltage will then enable, and the system will begin to cycle.
EOC and Vkey level gradually increases at start up due to AVIP function.
EOC is ON when EOC achieved
Key flash to indicate fire
HV is ON when enabled
LOCAL is ON for local operation
Interlock
Fault:
No
EOC
HV: ON
Vkey:
3950v
PSU:
OK
Load:
OK
CSP:
OK
Settings
Power: 250J
Level: High
Key:
Int
F/D:
0us
Rate: 1500ms
AVIP: 20%
F/F: Off
L/R: Local
Tca: 29°C
Tco: 16°C
Teo: 30°C