QC Log Format output per shot
QC Log is appended with EOC status:
$LOG,<EOC STATUS>,<POWER>,<LEVEL>,<TIME>,<DATE>,<32-BIT HEX KEY NUMBER>,
<KEY RATE>,<PRE-FIRE VOLTAGE>,<POST FIRE VOLTAGE>,<PEAK CURRENT>,
<TAMBIENT>,<TINLET>,<TOUTLET>,
<32-BIT HEX EVENT FLAGS>,<32-BIT HEX FAULT FLAGS>:
Example QC Logs:
$LOG,EOC=Y,01000J,LO,14:44:59,24-MAY-2018,00001786,0200ms,2504v,0022v,6446A,
25c,26c, 24c,00020080,00000000:
$LOG,EOC=N,01000J,LO,14:44:59,24-MAY-2018,00001786,0000ms,0000v,0000v,0000A,
25c,26c, 24c,00000000,00000001:
Note no termination log for QC Log Output.
Event Flags
Format is 32-bit hex long word.
Only flags logged are EOC flag (bit 7) and OPERATING flag (bit 17).
i.e for event flags 0x00020080, 2 is OPERATING flag & 8 is EOC flag.