POS MV V5 Installation and Operation Guide
Installation
2-24
receiver. The state of the auxiliary GNSS receiver input is displayed in the GNSS Data window, see
Figure 55 on page 8-2.
Obtain a cable and connector to suit the particular requirements of the GNSS receiver in use. Refer to
Table 3 on page 2-12 for the connector pin assignments of the COM ports.
Sonar Hardware and Acquisition Software
Any of the five COM ports may be used for connecting the sonar to the PCS. Note that Applanix strongly
recommend the use of an Ethernet interface in preference to serial for interfacing to sonar acquisition
systems. Unlike asynchronous serial messages, the Applanix defined Ethernet messaging (see PUBS-
ICD-004089 for details) includes a microsecond accurate time of validity.
Installation Parameters
Once the POS MV components are installed, the installation parameters must be measured. These
measurements allow the POS MV to deliver the best possible performance.
After you have configured the system with these parameters, save the data to non-volatile memory for
immediate use each time the POS MV is powered-on.
The POS MV configuration information defines the layout of the system and its associated peripheral
equipment relative to a reference point. The reference point is defined as any convenient location on the
survey vessel, and it may be assigned any orientation that you choose. Once you have decided on a
reference point, make the following measurements as carefully and accurately as possible.
Lever Arm Distances
Note:
Measure distances in metres, resolved into their longitudinal, lateral and vertical components in
the reference frame.
NB
POS MV uses a right-hand Cartesian co-ordinate system. Hence the lever arm offsets
should be entered using the following rules:
+X=to Bow, +Y=to Starboard, +Z=Down
NB
When using DGPS, lever arms should be measured to
rr
0.05m. When using RTK or
POSPac MMS IAPPK, lever arms should be measured to
r
0.005m.
•
Reference to IMU
Содержание POS MV V5
Страница 1: ...POS MV V5 Installation and Operation Guide Document PUBS MAN 004291 Revision 16 Date 29 August 2017 ...
Страница 2: ......
Страница 4: ......
Страница 40: ......
Страница 98: ...POS MV V5 Installation and Operation Guide Interfaces and Data Formats 3 24 ...
Страница 130: ...POS MV V5 Installation and Operation Guide System Configuration 4 32 Figure 39 POSView Controller Password Protection ...
Страница 156: ......
Страница 160: ......
Страница 174: ......
Страница 181: ...POS MV V5 Installation and Operation Guide Fault Identification Copyright Applanix Corporation 2017 9 7 ...
Страница 244: ......
Страница 248: ......
Страница 274: ......
Страница 282: ......