POS MV V5 Installation and Operation Guide
System
Operation
5-16
Stop logging - Ethernet Data Port
To stop Ethernet data logging, click the
Stop Logging
button on the
Ethernet Logging Control
screen
(Figure 45, page 5-11).
File Size Control - Ethernet Data Port
The following file size options are available for Ethernet logging:
x
One
Continuous
File
–
continuously log the Ethernet data over onto a single file
x
Split
at
64
MB
–
automatically split the Ethernet logged data in 64 MB files
x
Split at 128 MB - automatically split the Ethernet logged data in 128 MB files
x
Split at defined interval (min) - automatically split the Ethernet logged data after an elapsed
time in minutes (i.e. every 60 mins)
x
Split at defined time of day (hour) - automatically split the Ethernet logged data at a specific
time of day (i.e. at the 11
th
hour of each day)
Data Output – Ethernet
The Ethernet real-time data output port is intended for real-time control applications where the most
current position and orientation data are required. Real time data output on an Ethernet port is intended to
provide data for a third-party application that is capable of decoding the POS MV Ethernet ICD format.
Please refer to Applanix document
PUBS-ICD-004089
for a description of the Ethernet data output
format. These ports implement small storage buffers which are flushed frequently to ensure timely
delivery of the data.
Ethernet Real-Time
is used for real-time control applications,
whereas,
Ethernet Logging
has a large data buffer.
Start Output - Ethernet Realtime Data Port
To start Ethernet real-time data output, select
Settings
on the MV-POSView menu bar and
Ethernet
Real-time Port
on the drop-down menu. The window shown in Figure 49 appears.
Click on the tab for the port to be configured and then select the group or groups to be output by clicking
on the check box next to the group in the
Logging Group Select
pane. Select an output rate for group 1
(navigation solution), select a protocol, and finally, click the
Apply
button.
Содержание POS MV V5
Страница 1: ...POS MV V5 Installation and Operation Guide Document PUBS MAN 004291 Revision 16 Date 29 August 2017 ...
Страница 2: ......
Страница 4: ......
Страница 40: ......
Страница 98: ...POS MV V5 Installation and Operation Guide Interfaces and Data Formats 3 24 ...
Страница 130: ...POS MV V5 Installation and Operation Guide System Configuration 4 32 Figure 39 POSView Controller Password Protection ...
Страница 156: ......
Страница 160: ......
Страница 174: ......
Страница 181: ...POS MV V5 Installation and Operation Guide Fault Identification Copyright Applanix Corporation 2017 9 7 ...
Страница 244: ......
Страница 248: ......
Страница 274: ......
Страница 282: ......