POS MV V5 Installation and Operation Guide
Installation
Copyright © Applanix Corporation, 2017
2-9
2. Attach the IMU to the mounting location using four M5 ( #10 ) pan head bolts inserted through the
fixing holes in the base plate, isolating the IMU from the hull by way of an electrically non-
conductive material if possible. Use flat and shake proof washers under the IMU mounting
screws. Ensure that the flat washers (not shake proof washers) are placed in direct contact with
the IMU base plate.
3. Tighten the mounting bolts in a uniform manner, exercising care not to over torque. Avoid warping
the IMU base plate.
4. Attach the IMU connection cable to the IMU connector. Route the cable from the IMU to the PCS
mounting location. Avoid subjecting the cable to sharp bends or other mechanical stresses. Use
cable clips to secure the cable at regular intervals along its length.
5. Connect the IMU cable to the IMU port on the rear panel of the PCS.
6. After IMU installation, measure the lever arm distances and the mounting angles that POS MV
requires to generate its navigation solutions. Refer to page 2-24, Installation Parameters for
details of these parameters.
POS Computer System - POS MV V5
The PCS is the heart of the POS MV V5 systems. The PCS footprint is shown in Appendix E .
Install the PCS
Remove the PCS from its transit case to allow connection and operation. With the PCS removed from the
transit case, you can install, connect and use the unit in a 19 inch instrument rack where it occupies one
rack unit of space. Use an instrument rack that provides isolation against shock and vibration.
Observe the following installation constraints:
Do not hang the PCS from the loose panel mounting hardware.
Support the PCS weight from underneath while tightening the
panel mounting hardware.
•
Observe the environmental limitations starting on page 7-5.
•
Do not install the PCS where it may come into direct contact with water or high concentrations of
dust.
•
The PCS may be mounted in a shock isolating 19-inch instrument rack if one is available. The
PCS occupies one rack unit of space in a 19 inch instrument rack.
•
Do not mount the PCS to a vibrating surface or one that may experience severe shocks.
Содержание POS MV V5
Страница 1: ...POS MV V5 Installation and Operation Guide Document PUBS MAN 004291 Revision 16 Date 29 August 2017 ...
Страница 2: ......
Страница 4: ......
Страница 40: ......
Страница 98: ...POS MV V5 Installation and Operation Guide Interfaces and Data Formats 3 24 ...
Страница 130: ...POS MV V5 Installation and Operation Guide System Configuration 4 32 Figure 39 POSView Controller Password Protection ...
Страница 156: ......
Страница 160: ......
Страница 174: ......
Страница 181: ...POS MV V5 Installation and Operation Guide Fault Identification Copyright Applanix Corporation 2017 9 7 ...
Страница 244: ......
Страница 248: ......
Страница 274: ......
Страница 282: ......