POS MV V5 Installation and Operation Guide
Installation
Copyright © Applanix Corporation, 2017
2-11
Table 2: Connector/Cable Summary - POS MV V5
Connector
Cable
Description
LAN,
RJ-45
female
Straight
through or
Cross over
cable (meets
Cat5)
•
Ethernet interface communicates with a
controlling PC through this 10/100 Base-T
port
•
Port used to complete initial POS MV
configuration
Note
: The POS MV system may be configured in
the ‘AutoStart’ mode, so that subsequent operations
uses a standalone mode without the further need
for an Ethernet connection.
PPS,
BNC
female
75 ohm
coaxial cable
(RG59/U)
•
A TTL strobe at one pulse per second.
•
Output pulse polarity and pulse width is
configurable from POSView controller.
•
Leading edge of pulse is coincident with
exact GNSS second.
•
Provides synchronization with GPS Time.
Note
: D
o not
connect an input signal to the PPS
OUT port; otherwise, damage to the PCS interface
circuitry may result.
COM(1),
DE-9P
Single-
shielded cable
RS-232 Serial I/O port (digital)
COM(2),
DE-9P
Single-
shielded cable
RS-232 Serial I/O port (digital)
COM(3),
DE-9P
Single-
shielded cable
RS-232 / RS-422 (software switchable) Serial
I/O port (digital)
COM(4),
DE-9P
Single-
shielded cable
RS-232 / RS-422 (software switchable) Serial
I/O port (digital)
COM(5)1,
DE-9P
Single-
shielded cable
RS-232 Serial I/O port (digital)
GNSS1
Single-
shielded cable
Direct connection to COM port on internal
GNSS receiver for supplying corrections or
firmware upgrades.
ANT1,
TNC
female
50 ohm
coaxial cable
(RG303/U)
Supplies dc power to and receives signals
from primary GNSS antenna
ANT2,
TNC
female
50 ohm
coaxial cable
(RG303/U)
supplies dc power to and receives signals
from secondary GNSS antenna
[1]
–
COM5 and GNSS ports are only available on POS MV V5 part number PCS-84.
Содержание POS MV V5
Страница 1: ...POS MV V5 Installation and Operation Guide Document PUBS MAN 004291 Revision 16 Date 29 August 2017 ...
Страница 2: ......
Страница 4: ......
Страница 40: ......
Страница 98: ...POS MV V5 Installation and Operation Guide Interfaces and Data Formats 3 24 ...
Страница 130: ...POS MV V5 Installation and Operation Guide System Configuration 4 32 Figure 39 POSView Controller Password Protection ...
Страница 156: ......
Страница 160: ......
Страница 174: ......
Страница 181: ...POS MV V5 Installation and Operation Guide Fault Identification Copyright Applanix Corporation 2017 9 7 ...
Страница 244: ......
Страница 248: ......
Страница 274: ......
Страница 282: ......