POS MV V5 Installation and Operation Guide
System
Configuration
Copyright © Applanix Corporation, 2017
4-7
The subnet must be chosen carefully if UDP unicast is selected as the network protocol for real-time data
output. The user specified UDP unicast IP address must be within the same subnet as the POS IP
address in order for network communication to be functional. If the UDP unicast IP address is outside the
subnet, there will be no real-time output on the port that has UDP unicast selected.
A good rule of thumb is to keep the first three values of the POS and UDP unicast addresses the same
unless you must set a custom subnet.
POS MV Configuration
Once the POS MV components are installed and the physical installation parameters measured, these
measurements are then entered in to the MV-POSView Controller program. The PCS stores this data in
non-volatile memory for use on subsequent start-ups of POS MV.
The POS MV has a built-in feature that permits automatic fine-tuning of the configuration data. However,
the more accurate the initial physical measurements are the quicker the automatic fine-tuning process.
Figure 19 outlines the configuration data refinement process.
Figure 19: Configuration Data Refinement
Automatic fine-tuning permits the accurate measurement of the longitudinal, lateral and vertical distances
between the installed components. Accurate manual measurements are often difficult to obtain and are
subject to errors caused by accessibility. If it is not possible to measure the installation parameters to
within Real-Time Kinematic (RTK) level accuracy (about 2 cm) then the automatic lever arm calibration
feature should be used to improve accuracy. Although only the Reference to Primary GNSS
measurement is presently available, other automatic measurements will be available in the future.
Set the initial configuration of POS MV by performing the following.
a) Connect the PCS and the controlling PC to the 10/100BaseT Ethernet LAN. Both must have
compatible IP addresses; if necessary refer to the Changing Address description on page 4-5 for
instructions on IP addressing.
b) Power-on the PCS and the controlling PC, and start Microsoft Windows
®
; from windows, launch
the MV-POSView Controller program.
c) Select
Tools, Connect
on the MV-POSView main window menu bar.
Measure
Installation
Parameters
& Record
Configuration
Data
(Section 2)
Enter Initial
Configuration
Data into
MV-POSView
(Section 4)
Automatic
Fine-tuning of
Configuration
Data
(Section 4)
Auto
Calibration
Vessel
Prescribes a
Figure Eight
Содержание POS MV V5
Страница 1: ...POS MV V5 Installation and Operation Guide Document PUBS MAN 004291 Revision 16 Date 29 August 2017 ...
Страница 2: ......
Страница 4: ......
Страница 40: ......
Страница 98: ...POS MV V5 Installation and Operation Guide Interfaces and Data Formats 3 24 ...
Страница 130: ...POS MV V5 Installation and Operation Guide System Configuration 4 32 Figure 39 POSView Controller Password Protection ...
Страница 156: ......
Страница 160: ......
Страница 174: ......
Страница 181: ...POS MV V5 Installation and Operation Guide Fault Identification Copyright Applanix Corporation 2017 9 7 ...
Страница 244: ......
Страница 248: ......
Страница 274: ......
Страница 282: ......