POS MV V5 Installation and Operation Guide
Tools
and Diagnostics
Copyright © Applanix Corporation, 2017
8-5
•
Status
provides connectivity information. The main status field can be any of the following,
provided their conditions are met:
o
Online:
The PCS is receiving observables/corrections and already has the base
position. RTK is working as expected.
o
Waiting for base position:
The PCS is receiving observables/corrections but has
not yet received the base position. Wait until it has been received or check if the base
position is being transmitted to the PCS.
o
Receiving bad data:
The PCS is receiving data but it cannot be decoded. Check the
baud rate and selected communications protocol the PCS is set to and make sure
they match with your corrections provider.
o
Waiting for data:
The PCS is setup to receive corrections data but it is currently not
receiving data. Check the physical connection and make sure your corrections
provider is outputting data.
o
Offline:
The PCS is not setup to receive corrections.
•
Base Messages
provides a summary of the types of messages that have been received,
regardless of the specified message protocol.
•
Diagnostics
provides fields relating to the health of the messages.
•
Message Faults
provides a list of faults for incoming messages and the number of times they
have been encountered.
The details tab contains lists of messages and the number of times they have been successfully recorded
by the PCS. The messages are split up based on the message protocol they belong to. This can be seen
in Figure 58 below.
Содержание POS MV V5
Страница 1: ...POS MV V5 Installation and Operation Guide Document PUBS MAN 004291 Revision 16 Date 29 August 2017 ...
Страница 2: ......
Страница 4: ......
Страница 40: ......
Страница 98: ...POS MV V5 Installation and Operation Guide Interfaces and Data Formats 3 24 ...
Страница 130: ...POS MV V5 Installation and Operation Guide System Configuration 4 32 Figure 39 POSView Controller Password Protection ...
Страница 156: ......
Страница 160: ......
Страница 174: ......
Страница 181: ...POS MV V5 Installation and Operation Guide Fault Identification Copyright Applanix Corporation 2017 9 7 ...
Страница 244: ......
Страница 248: ......
Страница 274: ......
Страница 282: ......