POS MV V5 Installation and Operation Guide
System
Configuration
Copyright © Applanix Corporation, 2017
4-21
Save Settings
Changes made to the POS MV parameters will have an immediate effect on system operation. However,
if you require the changes to apply to all future occasions when you power-on the POS MV, you must
save them to NVM.
The non-volatile memory is resident in the PCS so that all stored operating parameters will be available to
the system during the start-up sequence, even when it operates in a stand-alone configuration.
To save the system parameters to NVM, select
Settings, Save Settings
from the MV-POSView menu
bar.
Note:
If you do not save any new settings for the installation parameters to NVM, POS MV will apply the
values stored previously (or the factory default values) when you next power-on the system.
Initial GNSS Configuration
Applanix supplies POS MV with two GNSS receiver cards installed in the PCS and optimally configured
for use with the system.
If either of the GNSS receivers loses its configuration for any reason, the PCS will reconfigure the
receiver cards automatically for its own use. The messages supplied by the GNSS receivers are only
those required by POS MV.
If you ever need to configure the installed GNSS receivers manually, you must select
Tools, Configure
GNSS
from the menu bar window of the MV-POSView Controller program.
Antenna Installation Calibration
A successful antenna installation calibration depends upon the GNSS Azimuth Measurement Subsystem
(GAMS) being able to use data from five or more satellites with a Positional Dilution of Precision (PDOP)
equal to or less than three. Perform the antenna installation calibration at a time when there is good
satellite geometry.
Note
: Applanix recommends that the user make use of the GNSS mission planning software to identify
an optimal time of day during which the PDOP is at a minimum in order to achieve a good GAMS
calibration.
Perform the following steps with the vessel under way in an area where unrestricted manoeuvring is
possible. You have the option of allowing POS MV to start the calibration automatically (this is called a
calibration auto-start) or to start the calibration manually.
1. Ensure that MV-POSView is
Connected
as indicated in the status bar, refer to
2. Figure 40 on page 5-3.
Содержание POS MV V5
Страница 1: ...POS MV V5 Installation and Operation Guide Document PUBS MAN 004291 Revision 16 Date 29 August 2017 ...
Страница 2: ......
Страница 4: ......
Страница 40: ......
Страница 98: ...POS MV V5 Installation and Operation Guide Interfaces and Data Formats 3 24 ...
Страница 130: ...POS MV V5 Installation and Operation Guide System Configuration 4 32 Figure 39 POSView Controller Password Protection ...
Страница 156: ......
Страница 160: ......
Страница 174: ......
Страница 181: ...POS MV V5 Installation and Operation Guide Fault Identification Copyright Applanix Corporation 2017 9 7 ...
Страница 244: ......
Страница 248: ......
Страница 274: ......
Страница 282: ......