SW Version 2.04
30-January-2009
Page 71 of 128
Table
Repetition
rate (ms)
Supported function
PAT
200
Regenerated from input.
Should always be transmitted
CAT
1000
Regenerated from input.
Must be transmitted if EMMs are specified to be
transmitted. (Pass-through or broadcast)
PMT
200
Regenerated from input.
Service ID and component pids may be remapped.
The PMT pid itself is not possible to change.
NIT
1000
Regenerated from input.
Supported in MPTS mode only. NIT is generated
based on the values entered by user. All
transports defined in the same network will be
included in NIT.
NIT Other is not supported.
IF NIT is not enabled then PID 16 (0x0010) will
not be transmitted.
The NIT supports the Nordig Logic Channel
Descriptor.
SDT-A
1000
The Service name can be modified.
The SDT sorting is based on the input slot, port
and the incoming SDT. I.e. the service listed first
in the SDT is the first service from port 0 in slot 1.
SDT-O
Not supported
EIT P/F-A
1000
Regenerated from input.
Supported in MPTS mode only.
EIT P/F-O
5000
Regenerated from input.
Supported in MPTS mode only.
Configuration of the PSI is designed to offer a global default configuration as well as
configurations of individual tables for each output port. Global configuration can be
used as default, or if need be individual services can be configured independently.
PSI configuration using preset defaults:
Open the
PSI Tables Base Values
dialog. This is achieved by clicking
Outputs
Æ
PSI
. The dialog is shown below.