SW Version 2.04
30-January-2009
Page 20 of 128
4.3.2
Manual PSI
The Manual PSI feature allows manual definition of input PSI. This feature is normally
not used as most inputs do contain correct PSI. In some cases however it is beneficial
to define the PSI manually.
The input does not contain PSI, or in-correct PSI.
The input is not available, and a pre-definition of the PSI is necessary in order to
configure a service that is occasionally available. This could for instance be used to
predefine some services for a dynamic VOD usage.
To manually define input PSI go to the Inputs->Manual PSI tab in the Navigation tree.
Enter the appropriate values matching the incoming stream. Note that the PMT PID
may be defined to any value between 32->8190, but make sure it is unique in an
MPTS configuration scenario. Also be aware if this input is part of an outgoing digital
stream the PMT PID entered here is the PID value that will be assigned for the
outgoing PMT.
When an input service is defined the following tables are generated:
PAT
1 Video PID
PMT
1 Audio PID with Language descriptor from audio
All other table analysis is cancelled.