SW Version 2.04
30-January-2009
Page 105 of 128
Figure 74 - Opening of air vents
When all the new modules have been inserted into the chassis, please make sure that
the front is completely closed using front panels. Leaving a slot position open without
a module or front panel will cause the unit to draw false air and consequently could
result in over-heating of the modules in the chassis.
To permanently remove modules from a specific slot position, the modules should first
be removed from the chassis. Next, select the
About
folder in the navigation tree. All
missing modules will be shown as red. To permanently remove the configuration of
the module from the chassis, select
Accept Changes
. This will permanently remove
the missing modules from the database.
When replacing an existing card, please note that a module configuration always
follows the slot position and not the module itself. Consequently, if a module is moved
from one slot in the chassis to a new slot, the unit will report the original slot position
as hardware missing, while the new slot position will be configured as a new card with
default configuration. Hence if a card is to be replaced it is important that the same
slot is re-used for the replaced card.
6.6
Configuration Import and Export
The configuration of a unit can be saved to file for later retrieval. The file contains the
entire configuration, except the MMI IP address. Right click on ‘Save to file’ to save
the current configuration.
To retrieve the configuration from a file, select the file, mark ‘Include Data Port IP
Addresses’ if the data port IP addresses should be included, and press ‘Restore’.