43
code HG0141.00GB ed.A-2008
LRP - RAPID PRO and LK - KONDENSA
LRP and LK WARM AIR HEATER
TYPE OF GAS G30 - Cat. 3B-P
TYPE OF MACHINE
LRP018
LRP028
LRP035
LRP045
LRP055
LRP075
RLP102*
min max min max min max min max min max min max min max
CATEGORY
according to the country of destination - see reference table
SUPPLY PRESSURE
[mbar]
30 [min 25-max 35] - 37 [min 42.5-max 57.5] - 50 [min 42.5-max 57.5]
PILOT NOZZLE Ø
[mm]
0.51
GAS CONSUMPTION
(15°C-1013mbar)
[kg/h] 0.84 1.37 1.33 2.24 1.68 2.89 2.16 3.65 2.47 4.33 3.68 6.10 4.15 8.63
CARBON DIOXIDE -CO
2
CON-
TENT
[%]
9.9
10
9.9
10
9.9
10
9.7
9.8
9.7
9.9 10.2 10.3 10.3 10.4
FLUE GAS TEMPERATURE
[°C]
75
204
70
191
70
170
75
190
80
175
80
190
80
194
GAS ORIFICE PLATE
[mm]
2.6
3.7
4.1
5.3
4.8
5.9
7.5
AIR ORIFICE PLATE
[mm]
15.5
Not required
* Maximum nominal heat output 104.0 kW
TYPE OF GAS G31 - Cat. 3P
TYPE OF MACHINE
RP018
LRP028
LRP035
LRP045
LRP055
LRP075
LRP102
min max min max min max min max min max min max min max
CATEGORY
according to the country of destination - see reference table
SUPPLY PRESSURE
[mbar]
30 [min 25-max 35] - 37 [min 25-max 45] - 50 [min 42.5-max 57.5]
PILOT NOZZLE Ø
[mm]
0.51
GAS CONSUMPTION
(15°C-1013mbar)
[kg/h] 0.80 1.35 1.26 2.21 1.59 2.85 2.05 3.60 2.35 4.27 3.50 6.01 4.09 8.18
CARBON DIOXIDE -CO
2
CON-
TENT
[%]
9.7
9.8
9.7
9.8
9.6
9.7
9.6
9.7
9.7
9.8
9.7
9.8
9.7
9.8
FLUE GAS TEMPERATURE
[°C]
75
204
70
191
70
170
75
190
80
175
80
190
80
194
FLUE GAS MASS FLOW
RATE (MAX.)
[kg/h]
GAS ORIFICE PLATE
[mm]
2.6
3.7
4.1
5.3
4.8
5.9
7.5
AIR ORIFICE PLATE
[mm]
15.5
Not required