![Anybus CompactCom 40 EtherNet/IP Скачать руководство пользователя страница 99](http://html1.mh-extra.com/html/anybus/compactcom-40-ethernet-ip/compactcom-40-ethernet-ip_network-manual_2948758099.webp)
99
Doc.Id. HMSI-27-212
Anybus CompactCom 40 EtherNet/IP
Doc.Rev. 1.5
9.5 Network Configuration Object (04h)
Category
Extended
Object Description
This object holds network specific configuration parameters that may be set by the end user. A reset
command (factory default) issued towards this object will result in all instances being set to their default
values.
If the settings in this object do not match the configuration used, the Module Status LED will flash red
to indicate a minor error.
The object is described in further detail in the Anybus CompactCom 40 Software Design Guide.
See also...
• “Communication Settings” on page 16
• “TCP/IP Interface Object (F5h)” on page 87 (CIP-object)
• “Ethernet Link Object (F6h)” on page 90 (CIP-object)
• “E-mail Client” on page 32
Supported Commands
Object:
Get_Attribute
Reset
Instance:
Get_Attribute
Set_Attribute
Get_Enum_String
Object Attributes (Instance #0)
# Name
Access
Data Type
Value
1 Name
Get
Array of CHAR ‘Network Configuration’
2 Revision
Get
UINT8
01h
3 Number of instances
Get
UINT16
000Fh (15)
4 Highest instance no.
Get
UINT16
0013h (19)