![Anybus CompactCom 40 EtherNet/IP Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/anybus/compactcom-40-ethernet-ip/compactcom-40-ethernet-ip_network-manual_2948758086.webp)
CIP Objects
86
Doc.Id. HMSI-27-212
Anybus CompactCom 40 EtherNet/IP
Doc.Rev. 1.5
Instances Attributes (Instance #1)
Extended
This instance reflects the properties associated with the Ethernet interface.
See also...
• “CIP Port Configuration Object (0Dh)” on page 153
Instances Attributes (Instances #2... #8)
Extended
See also...
• “CIP Port Configuration Object (0Dh)” on page 153 ( “Instance Attributes” on page 154)
# Name
Access Type
Value
1 Port Type
Get
UINT
0h (default)
4h (if the application registers a port)
2 Port Number
Get
UINT
2h
3 Link Object
Get
Struct of:
UINT
Padded EPATH
-
2h (Path Length)
20 F5 24 01h (Link Path)
4 Port Name
Get
SHORT_STRING “EtherNet/IP”
5 Port Type Name
Get
SHORT_STRING “”
6 Port Description
Get
SHORT_STRING “”
7 Node Address
Get
Padded EPATH
-
# Name
Access Type
Value
1 Port Type
Get
UINT
Enumerates the type of port
2 Port Number
Get
UINT
CIP port number associated with this port
3 Link Object
Get
Struct of:
UINT
Padded EPATH
-
Path length (number of 16-bit words)
Logical path segments which identify the object for this port.
The path must consist of one logical class segment and one
logical instance segment. The maximum size is 12 bytes.
4 Port Name
Get
SHORT_STRING Name of port, e.g. “Port A”. Max. 64 characters.
5 Port Type Name
Get
SHORT_STRING “”
6 Port Description
Get
SHORT_STRING “”
7 Node Address
Get
Padded EPATH
Node number of this device on port. The range within this data
type is restricted to a Port Segment.
8 Port Node Range
Get
Struct of:
UINT (Min.)
UINT (Max.)
-
Min. node number on port
Max. node number on port