154
Doc.Id. HMSI-27-212
Anybus CompactCom 40 EtherNet/IP
Doc.Rev. 1.5
Object Attributes (Instance #0)
Instance Attributes
Extended
See also...
• “Port Object (F4h)” on page 85 ( “Instances Attributes (Instance #1)” on page 86)
• “Port Object (F4h)” on page 85 ( “Instances Attributes (Instances #2... #8)” on page 86)
# Name
Access
Data Type
Value
1 Name
Get
Array of CHAR ‘CIP Port Configuration’
2 Revision
Get
UINT8
01h
3 Number of instances
Get
UINT16
-
4 Highest instance no.
Get
UINT16
-
11 Max. no. of instances Get
UINT16
0008h
# Name
Access
Type
Description
1 Port Type
Set
UINT16
Enumerates the port
a
a. See CIP specification, available from www.odva.org.
2 Port Number
Set
UINT16
CIP port number associated with this port
3 Link Path
Set
Array of UINT8 Logical path segments which identify the object for this port.
4 Port Name
Set
Array of CHAR String (max. no. of characters is 64) which names the port.
5 -
-
-
(reserved)
6 -
-
-
(reserved)
7 Node Address
Set
Array of UINT8 Node number of this device on port. The data type restricts
the range to a Port Segment. The encoded port number
must match the value specified in attribute #2.
A device which does not have a node number on the port
can specify a zero length node address within the Port Seg-
ment (i.e. 10h 00h).
In case the node address changes during runtime, the host
application is responsible for updating this attribute as well.
8 Port Node Range
Set
Struct of:
UINT16 (Min)
UINT16 (Max)
Minimum and maximum node number on port.
Support for this attribute is conditional; the attribute shall be
supported provided that the node number can be reported
within the range of the data type (e.g. DeviceNet). If not (as
is the case with networks such as EtherNet/IP which uses a
4 byte IP address), the attribute shall not be supported.