Doc.Id. HMSI-27-212
Anybus CompactCom 40 EtherNet/IP
Doc.Rev. 1.5
Instance Attributes (Instance #3, IP Address)
Extended
Instance Attributes (Instance #4, Subnet Mask)
Extended
Instance Attributes (Instance #5, Gateway Address)
Extended
# Name
Access
Type
Description
1 Name
a
a. Multilingual, see “Multilingual Strings” on page 107.
Get
Array of CHAR ‘IP address’
2 Data type
Get
UINT8
04h (= UINT8)
3 Number of elements
Get
UINT8
04h (four elements)
4 Descriptor
Get
UINT8
07h (read/write/shared access)
5 Value
Get/Set
Array of UINT8 Any change is valid after reset.
Valid range: 0.0.0.0 - 255.255.255.255 (Default =0.0.0.0)
6 Configured Value
Get
Array of UINT8 Holds the configured value, which will be written to attribute
#5 after the module has been reset.
Valid range: 0.0.0.0 - 255.255.255.255 (Default =0.0.0.0)
# Name
Access
Type
Description
1 Name
a
a. Multilingual, see “Multilingual Strings” on page 107.
Get
Array of CHAR ‘Subnet mask’
2 Data type
Get
UINT8
04h (= UINT8)
3 Number of elements
Get
UINT8
04h (four elements)
4 Descriptor
Get
UINT8
07h (read/write/shared access)
5 Value
Get/Set
Array of UINT8 Any change is valid after reset.
Valid range: 0.0.0.0 - 255.255.255.255 (Default =0.0.0.0)
6 Configured Value
Get
Array of UINT8 Holds the configured value, which will be written to attribute
#5 after the module has been reset.
Valid range: 0.0.0.0 - 255.255.255.255 (Default =0.0.0.0)
# Name
Access
Type
Description
1 Name
a
a. Multilingual, see “Multilingual Strings” on page 107.
Get
Array of CHAR ‘Gateway’
2 Data type
Get
UINT8
04h (= UINT8)
3 Number of elements
Get
UINT8
04h (four elements)
4 Descriptor
Get
UINT8
07h (read/write/shared access)
5 Value
Get/Set
Array of UINT8 Any change is valid after reset.
Valid range: 0.0.0.0 - 255.255.255.255 (Default =0.0.0.0)
6 Configured Value
Get
Array of UINT8 Holds the configured value, which will be written to attribute
#5 after the module has been reset.
Valid range: 0.0.0.0 - 255.255.255.255 (Default =0.0.0.0)