Basic Operation
16
Doc.Id. HMSI-27-212
Anybus CompactCom 40 EtherNet/IP
Doc.Rev. 1.5
2.3 Communication Settings
As with other Anybus CompactCom products, network related communication settings are grouped in
the Network Configuration Object (04h).
In this case, this includes...
• TCP/IP settings
These settings must be set properly in order for the module to be able to participate on the net-
work.
The module supports DHCP, which may be used to retrieve the TCP/IP settings from a DHCP-
server automatically. DHCP is enabled by default, but can be disabled if necessary.
• Physical Link Settings
By default, the module uses auto negotiation to establish the physical link settings, however it is
possible to force a specific setting if necessary.
The parameters in the Network Configuration Object (04h) are available from the network through the
built in web server, and through the TCP/IP Interface Object (CIP).
See also...
• “Web Server” on page 24
• “TCP/IP Interface Object (F5h)” on page 87 (CIP)
• “Ethernet Link Object (F6h)” on page 90 (CIP)
• “Network Configuration Object (04h)” on page 99 (Anybus Module Object)
• “Secure HICP (Secure Host IP Configuration Protocol)” on page 192