8
Scale
01-2020
Antti-Teollisuus Oy
STAGE 3
INSTALLING THE METER IN THE PANEL
Make an opening (92 mm x 45mm) in the panel in accordance with the illustration below.
Leave an area of (54mm x140 mm) next to the rim of the opening free from any installa
-
tions as shown in the illustration. Insert the meter in the opening with its rear part first and
fix it using the installation kit. Attach the sealing around the rim of the opening between the
meter and the panel. After installation the panel´s protection class on the frontside is IP 65.
The inside of the panel must be free of any moisture or dust.
STAGE 4
BASIC CONNECTIONS OF THE METER
The 230-V power supply for the panel meter may be taken from behind the control centre
of the dryer from the pilot fuse.
For basic use, only connect the terminals 1-6 at the rear of the scale display. Terminals 7-
10 are client inputs that need not be connected. Terminals 12-15 are put to use if an op-
tional serial communication card (RS 232) for the printer is installed. Terminals 16-19 are
put to use if an analogue card is installed inside the display. The analogue card makes it
possible to transmit the scale readout to the panel display on the logic centre or to the PC
control. The terminals 20-25 are not in use.
DIMENSIONS (mm)
CLEAR AREA REQUIRED BY METER
OPENING IN PANEL