16
Scale
01-2020
Antti-Teollisuus Oy
dsp 1
0
Defining the displayed 0-value for the
first calibration point, do not change the
factory setting (-19990 - 99999)
1Np 2
****
No changes
dsp 2
****
No changes
pro
NO
Moving to programming mode (
PRO
) or
returning to start mode (
NO
)
pro
1-1Np
Select the 1-INP menu
10X
1Np 2
****
Defining the value for the second calibra
-
tion point. The value is defined by sum
-
ming up the value (
1NP 1
) that you wrote
down to 20000 .***
dsp 2
80000
Defining the displayed value for the
second calibration point. Set the value to
80000, using the keys
and
***
Pro
NO
Moving to programming mode (
PRO
) or
returning to start mode (
NO
)
end
Exiting the programming mode
INP1
Voltage data from the sensors while the dryer is
empty (0 kg).
INP2
Calculated voltage data from the sensors at max.
load (80 000kg). INP 2 = INP 1 + 20.000
* Level of digital filtration is defined by means of time constant between 0-25
s. The filtration rate increases as the value increases. Increasing the filtra
-
tion rate improves the legibility of the display if the displayed value varies a
lot
** This parameter is used for setting the variation range for active digital
filtration. If the limits of the set range are exceeded, the filtration is switched
off and the readout is immediately shown on the display.
*** While depressing
the key in combination with the
or
keys, the value will change by 1 000 every time the key is depressed
**** Value that depends on the instance