18
Scale
01-2020
Antti-Teollisuus Oy
PROGRAMMING MENU 7 - PROGRAMMING OF SERIAL COMMUNICATION
This menu is for programming the serial communication port that is available as an option
for the PAXD meter. The serial communication port makes it possible to use a printer. Suc-
cessful data transfer requires that the RS232 set parameters of the meter match the set-
tings of the connected printer.
Depress the PAR key on the scale once. While "PRO" is shown on the display, press the
F1^ button repeatedly until 7-SRL shows on the display. Move forward in the menu by de-
pressing the PAR key and depress the F1^ key to change the settings.
Setting the serial communication card
Press
Param-
eter
Value
or sta-
tus
Description
Pro
No
Moving to programming mode (
PRO
) or
returning to start mode (
NO
)
7X
Pro
7-Ovt
Selecting settings for serial communica-
tion card(
7-srL
)
baud
2400
Set the data transfer rate to 2400 Baud,
using the buttons
and
(300, 600, 1200, 2400, 4800, 9600,
19200)
data
7
Set the data bit rate to 7, using
the buttons
and
(7, 8)
par
NO
Select "no parity"
using the buttons
and
(no, odd, even)
Addr
0
Set address to 0.
Abrv
yes
Accept transfer of abbreviation by select-
ing "yes"
Opt
NO
Select "no" for parameters to be printed.
Pro
NO
Moving to programming mode (
PRO
) or
returning to start mode (
NO
)
EnD
Exiting the programming mode
Содержание 408050
Страница 2: ......
Страница 4: ...4 Scale 01 2020 Antti Teollisuus Oy ...
Страница 10: ...10 Scale 01 2020 Antti Teollisuus Oy CONNECTING THE SCALE 4 SENSORS SCALE DISPLAY CONNECTING BOX SCALE SENSORS ...