background image

13

Antti-Teollisuus Oy

Scale

01-2020

APPEARANCE OF DISPLAY AND FRONT PANEL KEYS:

Display mode

Displayed unit se-

lected by client

Alarm display

Keys

DESCRIPTION

Selecting display mode

Switching over to programming mode

Function key 1, keep depressed for 3 seconds to display secondary function

Function key 2, keep depressed for 3 seconds to display secondary function

Function key 3, usually one of the reset-functions is programmed in this key

DESCRIPTION

Finishes programming and returns the display to normal operation mode

Saves the set value of parameter and moves to following parameter

Increases the set value of edited parameter by one unit

Increases the present value of the parameter by one unit

While kept depressed, increases the value of parameter by 1000, provided that one of 

the keys F1   or F2    is also depressed

DESCRIPTION

Displays the max. readout that the meter has saved

Displays the min. readout that the meter has saved

Displays the readout of the summarizing counter

Indicates the status of the preset value 1 (ON/OFF)

Indicates the status of the preset value 2 (ON/OFF)

Indicates the status of the preset value 3 (ON/OFF)

Indicates the status of the preset value 4 (ON/OFF)

KEY

DSP

PAR

F1

F2

RST

FUNCTIONS OF THE KEYS WHILE THE METER IS IN THE PROGRAMMING MODE

KEY

DSP

PAR

F1

F2

RST

INDICATORS SHOWN ON THE DISPLAY

INDICATOR

MAX

MIN

TOT

SP1

SP2

SP3

SP4

Содержание 408050

Страница 1: ...Installation and Operating Instructions Scale 408050 en ANTTI TEOLLISUUS OY Koskentie 89 25340 KANUNKI Puhelin 02 774 4700 E mail antti teollisuus fi www antti teollisuus fi 01 2020 ...

Страница 2: ......

Страница 3: ... be equipped with flexible parts The dryer in which the sensors are installed must be located indoors and must not come in contact with any other structures of the dryer Note If 2 sensors are installed they must be located under legs on the same side of the dryer see Illustration Scale sensor Base Base Antti Teollisuus delivers scale sensors with capacity of 20 000 kg Thus total weight of dryer ma...

Страница 4: ...4 Scale 01 2020 Antti Teollisuus Oy ...

Страница 5: ... being installed we recommend using a connection box Join the cables coming from the sensors inside the connection box Then the connection box and the panel meter will be connected by only one cable Solder all connections to avoid wrong reading due to poor contact General information of scale terminal i e PAXS panel meter The paxs panel meter is intended for use with strain gauge transducers speci...

Страница 6: ...in circuit board showing the position of each card and jumper connection are shown in the illustration on the next page The meter body is removed from the box by depressing firmly the finger grooves at the rear of the box and at the same time pulling out Once the finger grooves are depressed the catch screws are released from their slots in the box At first release one catch and after that the oth...

Страница 7: ...you check the jumper settings before resuming the operation After installation of any optional cards put the meter back in the box and ensure that the box is properly closed ANALOGUE OUTPUT SERIAL COMMUNICA TION CARD SLOT RELAY OUT PUT CARD SLOT FINGER GROOVE FINGER GROOVE USER INPUT INPUT MESSAGE AREA SENSOR VOLTAGE ...

Страница 8: ...nel must be free of any moisture or dust STAGE 4 BASIC CONNECTIONS OF THE METER The 230 V power supply for the panel meter may be taken from behind the control centre of the dryer from the pilot fuse For basic use only connect the terminals 1 6 at the rear of the scale display Terminals 7 10 are client inputs that need not be connected Terminals 12 15 are put to use if an op tional serial communic...

Страница 9: ...ntti Teollisuus Oy Scale 01 2020 Connecting the panel meter with two or four sensors Note If you are using four sensors you need a connecting box CONNECTING THE SCALE 2 SENSORS SCALE DISPLAY SCALE SENSORS ...

Страница 10: ...10 Scale 01 2020 Antti Teollisuus Oy CONNECTING THE SCALE 4 SENSORS SCALE DISPLAY CONNECTING BOX SCALE SENSORS ...

Страница 11: ... programming menus The programming menus include a number of different parameters The meter may be provided with desired param eters by changing the settings see next page Using the optional RS232 card requires setting of parameters 7 srl Using the optional analogue card requires setting of parameters 8 out Programming menu 1 Defining the settings for the input data and setting the meter scale Pro...

Страница 12: ...12 Scale 01 2020 Antti Teollisuus Oy PROGRAMMING DIAGRAM Perus näyttö PERUSASETUKSET LISÄASETUKSET EI MUUTOKSIA NÄIHIN ASETUKSIIN OPTIOASETUKSET START DISPLAY ...

Страница 13: ...parameter Increases the set value of edited parameter by one unit Increases the present value of the parameter by one unit While kept depressed increases the value of parameter by 1000 provided that one of the keys F1 or F2 is also depressed DESCRIPTION Displays the max readout that the meter has saved Displays the min readout that the meter has saved Displays the readout of the summarizing counte...

Страница 14: ...les between Display 1 parameter and Display 2 set value for the parameter To change the parameter depress the F1 and F2 keys repeatedly until the desired value is displayed After defining the parameter save it and move to the next parameter to be edited by pressing the PAR key Continue programming in this way until all the values that you wish to change have been processed Finally depress the DSP ...

Страница 15: ... the delimiter position Change the value using the keys and 0 0 0 0 00 0 000 0 0000 2X deCpt 0 Discard the decimals by setting the value to 0 roVnd 1 Defining the rounding Use the keys for changing the value and 01 02 05 10 20 50 100 3X roVnd 10 Set the value for rounding to 10 This means the weight will be rounded to nearest ten kilos fILtr 1 0 Digital filtration of the displayed value As require...

Страница 16: ...start mode NO end Exiting the programming mode INP1 Voltage data from the sensors while the dryer is empty 0 kg INP2 Calculated voltage data from the sensors at max load 80 000kg INP 2 INP 1 20 000 Level of digital filtration is defined by means of time constant between 0 25 s The filtration rate increases as the value increases Increasing the filtra tion rate improves the legibility of the displa...

Страница 17: ...ons 2 fNC usr 1 NO Function of 1st user input no changes usr 2 NO Function of 2nd user input no changes usr 3 NO Function of 3rd user input no changes f1 NO Function on 1st function key no changes F2 NO Function on 2nd function key no chang es 17X F2 Print Print print function is selected for the function key 2 rst NO Operation of the Reset key Go to point rst in the menu no rel d rel bat r tot r ...

Страница 18: ...u by de pressing the PAR key and depress the F1 key to change the settings Setting the serial communication card Press Param eter Value or sta tus Description Pro No Moving to programming mode PRO or returning to start mode NO 7X Pro 7 Ovt Selecting settings for serial communica tion card 7 srL baud 2400 Set the data transfer rate to 2400 Baud using the buttons and 300 600 1200 2400 4800 9600 1920...

Страница 19: ...rward in the menu by depressing the PAR key and depress the F1 key to change the settings Setting the analogue card Press Param eter Value or sta tus Description Pro No Moving to programming mode PRO or returning to start mode NO 8X Pro 8 Ovt Selecting settings for output card 8 Ovt type 4 20 Determine the output signal type from the analogue card 4 20mA 0 10V 0 20mA asIN 1NP Determine the output ...

Страница 20: ... Press Param eter Value or sta tus Description Pro No Moving to programming mode PRO or returning to start mode NO 9X Pro 9 fCS Select the maintenance menu 9 fCS d Lev 3 Adjust brightness of the display us ing buttons and 0 15 Code 66 Use code 66 for resetting the factory settings select using buttons and Pro NO Moving to programming mode PRO or returning to start mode NO EnD Exiting the programmi...

Страница 21: ...el of input signal Display readout drifts aimlessly Display becomes too sensitive or poor input data connec tions or the data transmitter has failed Check the filtration parameters rounding of readout scaling of input data in the Programming menu 1 and re check the input data connections as well as the condition of the transmitter You cannot ac cess desired pro gramming menu or parameters Optional...

Страница 22: ...part The guarantee does not cover the assembly and adjustment of the machinery A prerequisite for validity of the product guarantee is that the control system and the components used are approved by Antti Teollisuus Restrictions Compensation under the guarantee will not be remitted in the following cases 1 If the cause of the fault is normal wear abnormal operating conditions incorrect installatio...

Страница 23: ...aration of Conformity ANTTI TEOLLISUUS OY Koskentie 89 FI 25340 KANUNKI Tel 358 2 7744700 declares that SCALE conform with the provisions of the following directives Machine Directive 2006 42 EU Kuusjoki 03 01 2020 Kalle Isotalo Managing Director ...

Страница 24: ......

Отзывы: