The HEAT STOP function stops all production av radiator heat when the outside air temperature is equal to or
higher than the value entered for heat stop. When the heat stop function is activated, the circulation pump will
be turned off except when warm water is being produced. Even if shut off, the pump will be ”exercised” during 1
minute a day. Factory setting for heat stop is 17°C.
If you wish to change the HEAT STOP value:
1 Open the main menu INFORMATION by pressing the right- or left-hand button once.
You will find the cursor at the sub-menu OPERATION
2 Press the ”down” button to move the cursor to the sub-menu HEAT CURVE
3 Open the selected menu by pressing the right-hand button once.
4 You will find the cursor at the parameter CURVE.
5 Press the ”down” button to move the cursor to HEAT STOP
6 Open the selected parameter by pressing the right-hand button once. The cursor moves to HEAT STOP
7 Raise or lower the value, using respectively the ”up” or ”down” button.
8 Press the left-hand button three times to return to the main menu.
CONTROL
Adjuatmanet of the HEAT STOP value
Содержание AIR MAGNA 150
Страница 1: ...AIR MAGNA 150 INSTALLATION AND MAINTENANCE INSTRUCTIONS...
Страница 19: ...19 ELECTRICAL CONNECTION Part of wiring diagramm 2 5 mm terminal connection...
Страница 20: ...20 AIR MAGNA 150 GREEN ENERGY SYSTEMS Wiring Diagramm 230V 50Hz...
Страница 21: ...21 Wiring Diagramm 400V 3 50Hz...
Страница 43: ...43 COMPONENT PLACEMENT...
Страница 44: ...44 AIR MAGNA 150 GREEN ENERGY SYSTEMS COMPONENT PLACEMENT...
Страница 45: ...45 COMPONENT PLACEMENT 230 V 50 Hz 400 V 3 50 Hz...
Страница 47: ...47 DIMENSION Dimension and setting out coordinates...
Страница 49: ...49 DIMENSION Dimensions of the AIR MAGNA 150 10 outdoor unit Dimensions of the AIR MAGNA 150 12 outdoor unit...
Страница 52: ...52 AIR MAGNA 150 GREEN ENERGY SYSTEMS...