3. Tighten the core of the liquid valve (the smaller one) with valve key at first . After about 20 seconds, tighten
the core of the gas (the bigger one) with valve key. Turn off the machine at once and cut off the power supply.
4. Tighten the cap of two valves.
5. Disconnect the power cable from outdoor unit.
6. Loose the nut of the connect pipe to the outdoor unit valve with 2 spanner, disconnect the connect pipe and
the two valves.
· If the Outdoor Unit needs to be disconnected and moved to another place, please recycle the gas back into the
compressor according to the following steps before doing the disconnecting:
1. Start the machine, operate heat pump on state.
2. Remove the cap of two valves with the spanner.
PIPE CONNECTIONS
The step and diagram of collect refrigerant
Gas valve
Liquid valve
Gas valve
Liquid valve
Gas valve
Liquid valve
Gas valve
Liquid valve
Valve key
Valve key
Содержание AIR MAGNA 150
Страница 1: ...AIR MAGNA 150 INSTALLATION AND MAINTENANCE INSTRUCTIONS...
Страница 19: ...19 ELECTRICAL CONNECTION Part of wiring diagramm 2 5 mm terminal connection...
Страница 20: ...20 AIR MAGNA 150 GREEN ENERGY SYSTEMS Wiring Diagramm 230V 50Hz...
Страница 21: ...21 Wiring Diagramm 400V 3 50Hz...
Страница 43: ...43 COMPONENT PLACEMENT...
Страница 44: ...44 AIR MAGNA 150 GREEN ENERGY SYSTEMS COMPONENT PLACEMENT...
Страница 45: ...45 COMPONENT PLACEMENT 230 V 50 Hz 400 V 3 50 Hz...
Страница 47: ...47 DIMENSION Dimension and setting out coordinates...
Страница 49: ...49 DIMENSION Dimensions of the AIR MAGNA 150 10 outdoor unit Dimensions of the AIR MAGNA 150 12 outdoor unit...
Страница 52: ...52 AIR MAGNA 150 GREEN ENERGY SYSTEMS...