33
The MIN and MAX value is the lowest respectively highest value that is allowed for the supply line temperature.
Adjusting the minimum and maximum supply line temperature is particularly important if your home has floor
heating. If your house has floor heating and parquet floor, the supply line temperature should not be higher than
45°C.
Else the floor might get damaged. If you have floor coils and stone tiles, the MIN value should be 22-25°C in
summer when no heating is required – to obtain a comfortable floor temperature.
If there is a basement to your house, the MIN value should be adjusted to a suitable temperature in summer too, to
avoid a humid and chilly basement. In such cases, the value for HEAT STOP needs being adjusted upwards.
If you wish to change the MIN or MAX value:
1 Open the main menu INFORMATION by pressing the right- or left-hand button once.
You will find the cursor at the sub-menu OPERATION
2 Press the ”down” button to move the cursor to the sub-menu HEAT CURVE
3 Open the selected menu by pressing the right-hand button once. You will find the cursor at the parameter
CURVE.
4 Press the ”down” button to move the cursor to MIN.
5 Open the selected parameter by pressing the right-hand button once. The cursor is at MIN
6 Raise or lower the value, using the ”up” and ”down” button respectively.
7 Press the left-hand button three times to return to the main menu.
Repeat the procedure to change the MAX value, replacing MIN by MAX at step 4.
CONTROL
Adjustment of the MIN and MAX value
Содержание AIR MAGNA 150
Страница 1: ...AIR MAGNA 150 INSTALLATION AND MAINTENANCE INSTRUCTIONS...
Страница 19: ...19 ELECTRICAL CONNECTION Part of wiring diagramm 2 5 mm terminal connection...
Страница 20: ...20 AIR MAGNA 150 GREEN ENERGY SYSTEMS Wiring Diagramm 230V 50Hz...
Страница 21: ...21 Wiring Diagramm 400V 3 50Hz...
Страница 43: ...43 COMPONENT PLACEMENT...
Страница 44: ...44 AIR MAGNA 150 GREEN ENERGY SYSTEMS COMPONENT PLACEMENT...
Страница 45: ...45 COMPONENT PLACEMENT 230 V 50 Hz 400 V 3 50 Hz...
Страница 47: ...47 DIMENSION Dimension and setting out coordinates...
Страница 49: ...49 DIMENSION Dimensions of the AIR MAGNA 150 10 outdoor unit Dimensions of the AIR MAGNA 150 12 outdoor unit...
Страница 52: ...52 AIR MAGNA 150 GREEN ENERGY SYSTEMS...