CONTROL

Main Menu Information

Sub-Menu OPERATION

This menu is used for the selection of operating mode. The control system allows for five different operating modes:
 

· OPERATION HEAT PUMP ON : 

 

  Heat pump (compressor) operation is allowed by the control system.

 

· OPERATION HEAT PUMP OFF: 

 

  Heat pump (compressor) operation is not allowed by the control system.

 

· OPERATION ADD. HEAT ON/OFF: 

 

  The auxiliary heater will/will not be allow ed to operate. This operating mode is normally used when a  

 

 

          new installation is being put into service, before the brine system is ready for use.
 

· OPERATION AUTO : 

 

  Heat pump and auxiliary heater are regulated automatically by the control system. The text “OPERATION  

 

 

          AUTO” will be displayed on the control panel.
 

· OPERATION ROOMHEAT : 

 

  The heat pump will be distributed to the heating system only; The heat pump will not produce warm  

 

 

          water. The  text “OPERATION WARMWATER” will be displayed on the control panel.
 

· OPERATION WARMWATER : 

 

  The heat pump will only produce warm water; no heat will be istributed to the heating system. The text  

 

 

          ”OPERATION WARMWATER “will be displayed on the control panel.

To select the desired sub-menu use the up or down button. Open the menu by pressing the right-hand button once.
To return to the main menu, press the left-hand button once

To open the main menu INFORMATION, press the right- or left-hand button once.

Return
Open
next
menu

sub
menus

Содержание AIR MAGNA 150

Страница 1: ...AIR MAGNA 150 INSTALLATION AND MAINTENANCE INSTRUCTIONS...

Страница 2: ...n 24 Sub menu Operation 24 Sub menu Heat Curve 25 Sub menu Temperature 26 Sub menu Integral 26 Sub menu Operating Time 27 Sub menu Reset 28 Sub menu Man Test 28 Sub menu DEFROST 28 Adjustments to be m...

Страница 3: ...in the compressor The refrigerant the temperature of which has now been raised is passed to the condenser where it gives off its energy to the heating medium circuit and if necessary to the water hea...

Страница 4: ...he heating demand is taken care of by the heat pump compressor unit the auxiliary heater being started only when demands exceed available heat pump capacity AIR MAGNA 150 consists of five main compone...

Страница 5: ...the condenser The temperature of the refrigerant sinks and it returns to its liquid state d The heat energy released is carried by the heating circuit to water h eater and radiator or floor heating s...

Страница 6: ...tures a graphic display control buttons Beside the control panel you will find the User s Manual a short description of how to increase and reduce room temperature and a label with name and phone numb...

Страница 7: ...th a minus One button pointing to the right One button pointing to the left One button pointing to the Power ON OFF Symbols For you to know at a glance the actual operating mode of the heat pump one o...

Страница 8: ...backs on to a bedroom or living room Copper pipe connecting 1 The maximun length of the connecting copper pipe between the mainframe and outdoor unit is 15 meters 2 There is no need to charge extra r...

Страница 9: ...g assembly the pipes for the heat medium and water heater and possibly hot water circulation are routed backwards The distance between AIR MAGNA 150 and the wall ought to be 50 mm Copper pipe connecti...

Страница 10: ...ermostats must be removed to ensure sufficient flow Pipe connections water heater The heat pump s water heater must be fitted with the necessary valve equipment The heat pump should be supplemented wi...

Страница 11: ...he connecting pipe 5 Take off the nuts in the mouths of high valve and low valve turn the valves core anticlockwise with hexagon panner till the valves are opened completely Recover and tighten the nu...

Страница 12: ...he connect pipe to the outdoor unit valve with 2 spanner disconnect the connect pipe and the two valves If the Outdoor Unit needs to be disconnected and moved to another place please recycle the gas b...

Страница 13: ...13 PIPE CONNECTIONS Pump capacity diagrams heating medium side AIR MAGNA 150 6 8 10 12 Available pressue kPa Flow l s Available pressue kPe Flu l s WILO RS 25 8 AIR MAGNA 150 16 WILO RL 25 7 5...

Страница 14: ...AGNA 150 GREEN ENERGY SYSTEMS PIPE CONNCETIONS How to adjust the rate of flow The pump is adjustable to adjust the flow 1 2 or 3 WILO RS 25 8 WILO Rl 25 7 5 The pump is adjustable to adjust the flow 1...

Страница 15: ...CONNECTION Connect the power cord NOTE Electrical installation and service must be carried out under the supervision of a qualified electrician in accordance with the stipulations in force 230V 50Hz...

Страница 16: ...16 AIR MAGNA 150 GREEN ENERGY SYSTEMS ELECTRICAL CONNECTION Wirning of the terminal mode one Wirning of the terminal mode two Step1 Step2 Step3 Step1 Step2 Step3...

Страница 17: ...nnecting The Room Temperature Sensor Room temperature sensor RT Room temperature sensor Connecting The Outside Temperature Sensor OCT Outside air temperature sensor OUTP Defrost temperature sensor Out...

Страница 18: ...outdoor unit fan water cycle pump two and electrical heater four should be connected to the 1 5mm terminal through the hole on the sound insulation board and connect to outside with the copper pipes E...

Страница 19: ...19 ELECTRICAL CONNECTION Part of wiring diagramm 2 5 mm terminal connection...

Страница 20: ...20 AIR MAGNA 150 GREEN ENERGY SYSTEMS Wiring Diagramm 230V 50Hz...

Страница 21: ...21 Wiring Diagramm 400V 3 50Hz...

Страница 22: ...le of the three way valve for waterflow at the middle position 8 Press the power ON botton on the control panel and start the heating medium pump 9 The filling pump and the heating medium pump are now...

Страница 23: ...art per 15 minutes Readjusting heat medium side Air is initially released from the hot water and venting may be neces sary If bubbling sounds can be heard from the heat pump the entire system requires...

Страница 24: ...mand or not If there is there will also be symbols telling which heat source is working heat pump or auxiliary heater or both see Symbols on page 6 Which operating mode has been selected In addition t...

Страница 25: ...p and auxiliary heater are regulated automatically by the control system The text OPERATION AUTO will be displayed on the control panel OPERATION ROOMHEAT The heat pump will be distributed to the heat...

Страница 26: ...s supply line temperature when the outside air temperature ment of CURVE is 0 C value on p 27 MIN Adjustment of value for lowest supply line temperature allowed User see Adjust ment of MIN and MAX val...

Страница 27: ...stment of ROOM value on page 28 FEED Actual measured supply line temperature of heating system Not adjustable The in brackets the set point desired value temperature necessary to keep the desired room...

Страница 28: ...ll be closed USER ADD 3 When the value testing reaches the value setting by user the ADD3 will be start up And the value testing under the value setting the ADD3 will be closed USER Sub Menu OPERATING...

Страница 29: ...set by yourself DEF TIME The range of the setting defrost time 2 20 min Default value 15 min INTERVAL The range of the setting defrost interval 25 70 min Default value 40 min START TEMP The range of...

Страница 30: ...to supply line temperature This relation is referred to as heat curve Adjustment of the CURVE value The heat curve will be adjusted by the CURVE value This value indicates the supply line temperature...

Страница 31: ...tter Instead the whole curve is moved by 3 C for every degree by which the ROOM value is changed The relation supply line temperature to outside air temperature will not be affected The supply line te...

Страница 32: ...ximum adjustment is clearly visible As we have seen you can choose to adjust the heat curve at three specified out side air temperatures 5 C 0 C and 5 C The supply line temperature can be changed by p...

Страница 33: ...umid and chilly basement In such cases the value for HEAT STOP needs being adjusted upwards If you wish to change the MIN or MAX value 1 Open the main menu INFORMATION by pressing the right or left ha...

Страница 34: ...alue 1 Open the main menu INFORMATION by pressing the right or left hand button once You will find the cursor at the sub menu OPERATION 2 Press the down button to move the cursor to the sub menu HEAT...

Страница 35: ...eft hand button once You will find the cursor at the sub menu OPERATION 2 Press the down button to move the cursor to the sub menu TEMPERATURE 3 Open the menu by pressing the right hand button once 4...

Страница 36: ...ressing the right or left hand button once You will find the cursor at the sub menu OPERATION 2 Press the down button to move the cursor to the sub menu called TEMPERATURE 3 Open the menu by pressing...

Страница 37: ...of the Heating System The pressure of the heating system should be checked once monthly The pressure shown on the external pressure gauge should be 1 1 5 bar If the value is below 0 8 bar with cold wa...

Страница 38: ...ounts of water when the water heater is being charged especially if a lot of warm water was used previously To check the safety valves give the cap a quarter of a turn clockwise until the valve lets o...

Страница 39: ...eat protection cut out Electrical fault The safety switch has Check fuses and reset cut out safety switch if cut out OUT SENSOR Error outside air sensor Electrical fault Call your installation The val...

Страница 40: ...be adjusted on the control panel The value indicates the temperature of the water distributed to the radiators supply line temperature at an outside air temperature of 0 C Refrigerant Circuit in the h...

Страница 41: ...ater cycle pump BA M Control the fan motor of outdoor unit Initial state The initial state of the manual switch board are such buttons A0 AA BA all of them are off see the picture When the machine is...

Страница 42: ...emaining water can run out When the heating medium is empty the requisite service can be carried out Draining water tank First close the drain valve 73 74 And then open the drain valve 72 When the wat...

Страница 43: ...43 COMPONENT PLACEMENT...

Страница 44: ...44 AIR MAGNA 150 GREEN ENERGY SYSTEMS COMPONENT PLACEMENT...

Страница 45: ...45 COMPONENT PLACEMENT 230 V 50 Hz 400 V 3 50 Hz...

Страница 46: ...le pressure switch OFF 3 3MPa ON 2 4MPa 39 High pressure pressostat 40 High pressure pressostat OFF 2 9MPa ON 2 4MPa 41 Compressor 42 Oil tank 43 Drying filter 44 Waterspout 45 Condenser 46 Pressure r...

Страница 47: ...47 DIMENSION Dimension and setting out coordinates...

Страница 48: ...48 AIR MAGNA 150 GREEN ENERGY SYSTEMS DIMENSION Dimensions of the AIR MAGNA 150 6 outdoor unit Dimensions of the AIR MAGNA 150 8 outdoor unit...

Страница 49: ...49 DIMENSION Dimensions of the AIR MAGNA 150 10 outdoor unit Dimensions of the AIR MAGNA 150 12 outdoor unit...

Страница 50: ...50 AIR MAGNA 150 GREEN ENERGY SYSTEMS ACCESSORIES Enclosed kit 83 77 78 79 80 81 82 Dimensions of the AIR MAGNA 150 16 outdoor unit...

Страница 51: ...torage heater liters 9 8 9 8 9 8 9 8 12 20 Max pressure in spiral copper pipe volume MPa 0 9 9 bar Refrigerant quantity R407C MPa 0 25 2 5 bar Heating medium flow kg 1 15 1 08 1 50 1 85 1 95 Max temp...

Страница 52: ...52 AIR MAGNA 150 GREEN ENERGY SYSTEMS...

Страница 53: ...ANTEK INDUSTRIAL GROUP Office Boerhaavegasse 8A A 1030 Wien Office and Warehouse Donaul nde 11 A 2403 Regelsbrunn Tel 43 0 1 89 04 04 4 Fax 43 0 1 89 04 04 41 5 E Mail www info antek at www ANTEK Gree...

Отзывы: