General Safety Precautions
IMGT30017EN
-
vii
-
¾
GT3000 provides variable frequency control. Motors and loads must be capable of operation over the speed and power
range provided by the drive.
¾
Co-ordinate motor and drive voltage and current ratings. The rated voltage of the motor must be greater than 1/2 of the
input voltage, and the rated current of the motor must be greater than 1/3 of the output current of GT3000.
¾
Regardless of the output operating frequency, GT3000 produces a pulsed output voltage with a peak value of about 1.4
times the rated input AC voltage with very short rise times. The voltage of these pulses may almost double at the motor
terminals, depending on the cable properties. Make sure that output cables and motor insulation are designed to
withstand the additional stress.
¾
If isolation tests on the motor and cables must be performed, disconnect the cables from the drive first. Hi-potential tests
must not be performed on GT3000 components.
¾
Use caution not to damage any part of GT3000 while handling it.
¾
Protect the equipment from weather and incorrect environmental conditions (temperature, humidity, vibration, shock, etc.).
If drive must be temporarily stored outdoors, special precautions must be taken. (See Chapter 2A.2)
DO NOT
¾
operate the drive at voltages in excess of 10% of its maximum rated input
voltage.
¾
apply power to GT3000 output terminals.
¾
connect GT3000 drives in parallel directly on the output terminals
¾
connect capacitive loads to the GT3000 output terminals
¾
connect the drive input to the output (Bypass)
¾
If the drive has not been energized for a period of greater than two years it
is necessary to reform the electrolytic capacitors. Do this by energizing
GT3000 when not enabled (Drive Enable open) for a period of at least two
hours.
The drive contains components sensitive to electrostatic charges; such components may be damaged if incorrectly handled.
During replacement or maintenance of the electronic boards, the following steps must be adhered to:
¾
Use a maintenance kit for electrostatic charges. Electrostatic Discharge (ESD)
precautions must be taken:
¾
Wear properly grounded static straps.
¾
Handle PC boards by holding them by the edges.
¾
Boards must not come into contact with highly insulating materials, such as
plastic sheets, insulating surfaces, parts of synthetic fabrics.
¾
Boards must be placed only on conductive surfaces.
¾
Boards must be packaged in conductive sheets before shipping.
Equipment warranty and liability
Warranty
Refer to Answer Drives S.r.l. Sales General Conditions
(attached to the order confirmation) for warranty conditions.
Liability
Answer Drives S.r.l.. is not responsible neither for technical lack or mistake in this manual nor for
incidental damages consequential to the use of the information in this manual.
WARNING
WARNING
☞
Содержание GT3000
Страница 1: ...GT3000 Hardware Software Manual www answerdrives com ...
Страница 2: ......
Страница 4: ......
Страница 8: ...Table Of Contents GT3000 iv IMGT30017EN ...
Страница 12: ...General Safety Precautions viii IMGT30017EN ...
Страница 25: ...GT3000 Technical Data IMGT30017EN 13 Frames IV V VIN SVGT045 166 IP20 ...
Страница 26: ...Technical Data GT3000 14 IMGT30017EN Frames IV V VIN SVGT045 166 IP54 ...
Страница 27: ...GT3000 Technical Data IMGT30017EN 15 Frames IV V IP20 NEMA1 SVGT105 170K J Peso 65Kg Weight 143Lbs ...
Страница 28: ...Technical Data GT3000 16 IMGT30017EN Frames VII VIII IP00 SVGT200 521K SVGT200 470F ...
Страница 29: ...GT3000 Technical Data IMGT30017EN 17 F series Frames 2xVII 2xVIII Parallel IP00 SVGT520 940M ...
Страница 30: ...Technical Data GT3000 18 IMGT30017EN K series Frames 2xVII 2xVIII Parallel IP00 SVGT580 960K ...
Страница 32: ...20 IMGT30017EN 3A 1 3 Lifting Frame VII VIII Figure 2A 1 Methods of Unloading and Lifting GT3000 Drives ...
Страница 36: ...Installation GT3000 24 IMGT30017EN 3A 2 1 4 Frames VII VIII Installatiion ...
Страница 58: ...GT3000 Installation 46 IMGT30004EN ...
Страница 107: ...GT3000 Terminal Boards and Power Schematics IMGT30017EN 95 ...
Страница 108: ...Terminal Boards and Power Schematics GT3000 96 IMGT30017EN SVGT200 260 320K J Motor earth connection Field bus ...
Страница 109: ...GT3000 Terminal Boards and Power Schematics IMGT30017EN 97 SVGT390 521K J Field bus Motor earth connection ...
Страница 110: ...Terminal Boards and Power Schematics GT3000 98 IMGT30017EN ...