5.6.2 Load data
Press “Mode/Esc” key to the screen on the left, then press “Enter/
Start” key to enter the submenu.
You can press “Dec. </INC >” key to select the data number when
the (01) field is blinking.
Press “Enter/Start” key for more than 2 seconds,it will shows you the
left screen, loading the data.
6. Warning and Error Messages
The output is connected to a battery with incorrect polarity.
This will be displayed in case of detecting an interruption of the
connection between battery and output or voluntarily disconnecting
the charge lead during the operation of charge or discharge on
output.
There was a short-circuit at output. Please check the charging leads.
The voltage of input power drops below the limit.
The voltage of Lithium battery pack was selected incorrectly. Verify
the voltage of battery pack carefully.
There happens the malfunction at the charger circuit by any reason.
The processor detects the voltage is lower than you set at the Lithium
program. Please check the cell count of the battery pack.
The processor detects the voltage is higher than you set at the Lithium
program. Please check the cell count of the battery pack.
The voltage of one of the cell in the Lithium battery pack is too low.
Please check the voltage of the cell, one by one.
The voltage of one of the cell in the Lithium battery pack is too high.
Please check the voltage of the cell, one by one.
There are bad connection at the individual connector. Please check the
connector and cables carefully.
The internal temperature of the unit goes too high. Cool down the
unit.
The processor can not continue to control the feeding current by any
reason.The unit needs to be repaired.