Chapter 3 Application Ethernet
3-54
Test Mode pane
The Test Mode setup is similar to that of the RFC2544 Throughput test
setup. See section 3.8.1 for further details.
Duration pane
All RFC2544 tests are executed in steps. A step is a specific combination
of a frame size and burst size. During a step, a specific number of frames
with a specified size are transmitted back-to-back. The number of steps
run during a test depends on the selected number of frame sizes and
burst sizes.
The Step Duration time can be set in number of seconds (3 seconds) on
the Duration pane. This is approximately the time duration of each test
step.
The Test Repetitions field sets the number of times the complete test will
run. The possible setting range is 1 to 1000 times. The Duration pane is
similar to the RFC2544 Throughtput Duration pane; see Figure 3.8.1-3.
Destination pane
The Destination setup is similar to that of the Ping test setup. See 3.6.1
for further details.
Frame Size pane
The Frame Size pane has checkboxes for the predefined sizes 64, 128,
256, 512, 768, 1024, 1280, 1518 and Jumbo Frame. The jumbo frame size
can be set from 1519 to 10000. The Frame Size pane is similar to the
RFC2544 Throughtput Frame Size pane; see Figure 3.8.1-4.
Note
The RFC2544 test cannot be started without selecting at least one frame
size.
Содержание Mainframe MU909060A Series
Страница 10: ...For Safety x Laser Radiation Markings 1 2 A B D C Figure 1 Locations of Laser Beam Apertures and Affixed Labels...
Страница 24: ...IV...
Страница 54: ...Chapter 1 Outline 1 30...
Страница 56: ...Chapter 2 General Operation 2 2 2 9 PDF Reports 2 30 2 9 1 Setup 2 31 2 9 2 Generating a report 2 33...
Страница 61: ...2 2 General Functions 2 7 2 General Operation Power Down Starts power down...
Страница 164: ...Chapter 5 Pass through 5 8...
Страница 175: ...Appendix A Specifications A 1 Appendix Appendix A A 1 Specifications A 2 A 2 Parts and Accessories A 7...
Страница 182: ...Appendix A Specifications A 8...
Страница 190: ...Index Index 6...