Chapter 3 Application Ethernet
3-52
Note
The reference function requires the Throughput and Latency tests
to be in the same mode. Hence, it cannot be used when the Latency
test is in the Router Latency mode. The two tests must also use the
same port(s).
Using the Tolerance Level (utilization multiplier) field, it is possible to
tune the line loads used in the Latency test compared to the line loads
used in the referenced Throughput test. If the Tolerance Level is 100.0%,
the two tests use the same line loads; if 50.0% is set, the Latency test line
loads are half the line loads of the Throughput test, etc.
Advanced pane
The advanced setup is similar to that of the RFC2544 Throughput test
setup. See section 3.8.1 for further details.