3.8 RFC2544
Tests
3-51
3
Ether
n
et Applicat
ion
Line Load pane
The line load range used in the test is specified as Min: and Max. The
load is varied in intervals using the value specified in the Step field. The
test always starts at Max: and decreases until the line load is equal to
Min. Line loads are either in Mbps or as a percentage of the current line
speed. However, in the Router Latency mode, line loads are presented in
kbps.
Figure 3.8.2-2 RFC2544 Latency Setup Screen, Line Load Pane in
Router Latency Mode
The RFC2544 Latency test can reference a preceding RFC2544
Throughput test and only run passed steps. Select the Only run steps
where preceding test passed checkbox to enable this feature and select a
Throughput test in the Reference Test field.
Figure 3.8.2-3 RFC2544 Latency Setup Screen, Line Load Pane