English
Use and Installation
43
7
MAINTENANCE INSTRUCTIONS
The maintenance operations are to be performed by
qualified and authorised technical personnel, who
possess the specific knowledge needed to perform the
job without risk.
Before doing any maintenance work, depressurise the
water system and disconnect the electric pump from
the power source.
When the operations are completed, check that no
tools, rags, clothing or foreign materials have been
(1) This interval only refers to the first oil change
Safety recommendations for maintenance
Scheduled maintenance table
Interval
Component
Type of intervention
Reference
Every working day
Filter
Check the condition of the
filter cartridge
See “Regular inspection of the
filter“
Pump
Check the oil level
See “Checking the oil level“
Every 50 working hours
Electric pump
Check the tightness of the
mounting bolts
See “Inspecting the electric
pump mounting“
Lines and connections
Check
See “Inspection of the lines
and connections“
Pump
Change oil (1)
See “Changing the oil“
Every 100 working hours
(wobble-plate pump)
Pump
Change the oil
See “Changing the oil“
Electric motor
Check that the insulating parts
are in good condition
Electric motor cable clips and
cable terminals
Check that all the cable clips
and terminals are securely
tightened
Electric motor terminal box
and cable guides
Check that the terminal boxes
and cable guides are sealed to
prevent external agents from
entering
Every 200 working hours
(wobble-plate pump)
Pump gaskets
Replacement
Contact an authorised service
centre
Intake and delivery valves
Replacement
Contact an authorised service
centre
Every year or 500 working
hours
Pump
Change the oil
See “Changing the oil“
Electric motor
Check that the insulating parts
are in good condition
Electric motor cable clips and
cable terminals
Check that all the cable clips
and terminals are securely
tightened
Electric motor terminal box
and cable guides
Check that the terminal boxes
and cable guides are sealed to
prevent external agents from
entering
Every 800 working hours
Pump gaskets
Replacement
Contact an authorised service
centre
Intake and delivery valves
Replacement
Contact an authorised service
centre
Fan cover and blades
Clean the air passages
See “Cleaning the electric
motor fan cover and blades“
left near the moving parts before restarting the
electric pump.
Replace any worn components with original parts and
use the lubricants recommended by the manufacturer.
Dispose of the worn-out components and lubricants in
accordance with the relevant statutory requirements.
Regularly perform the routine maintenance
procedures specified by the manufacturer to keep the
electric pump safe and performing well.
Inspecting the electric pump mounting
Regularly check that the mounting bolts of the electric
pump are tight.
If the bolts are loose, tighten them to the driving torque
stated in the installation design.