7.3.6
Connecting the jumper cables 120V ONLY
Figure 7 - Jumper placement for 120V ONLY
Ok with this part of the IEC strip configured. we are now going to put in the jumpers required
for 120V operation. As you can see in
Figure 7
, you will solder an 18g wire from the white to the
White/Grey pad, then also do a Black to Black/Grey pad.
NOTE: This step is only for 120V, see next step if you are running a 240V system