Problem
Cause
Check
Solution
9. Paint leakage between the
a) Loosened suction tube
a) Tighten
main body and the suction
tube
b) The upper V packing (between the main body
b) Replace it
and the suction tube) is worn out or damaged
10. Paint leakage from the paint a) Loosened cylinder
a) Tighten it
filter (model with paint filter)
11. Air leakage from the air
a) Worn out or damaged O-rings (ref. Page 38
a) Replace them
motor
components 16-20)
b) Worn out or damaged washer (ref. page 38
b) Replace it
component 34)
c) Worn out block (ref. page 38 component 17)
c) Replace it
d) Damaged sleeve (ref. page 38 component 10)
d) Replace it
e) Loosened nut (ref. page 38 component 9)
e) Tighten or replace it, if
damaged