5.6
Daily interruptions
[ref. figure 2 page 17 and figure 3 page 18]
1. Upon interrupting the use of the pump:
- It is not necessary to disconnect the air supply, if the interruption is short.
- If the interruption period is long, turn the ball valve (E), discharge the air from the circuit and open
the recirculation valve (C) to release the residual fluid pressure.
2. When the pump is stopped at the end of the working day:
- Clean the fluid ducts.
- Remove the suction hose filter, the filter inside the compensating device (in the multi spray unit with fil-
ter), the gun filter and clean them.
5.7
Improper and dangerous uses
A wrong earthing, an insufficient ventilation, a naked flame or a spark can cause a fire or an
explosion and provoke some serious injuries.
WARNING
IF SPARKS OR AN ELECTRIC DISCHARGE ARE PERCEIVED, INTERRUPT IMMEDIATELY ALL
PAINTING OPERATIONS.
DO NOT USE THE SYSTEM UNTIL THE CAUSE OF THE PROBLEM IS IDENTIFIED.
Keep away from the working area all kinds of waste, solvent containers, solvent or petrol
soaked rags or clothes.
Before starting the system disconnect all the electrical connections inside the working area.
Before using the system switch off all the naked flames and pilot lights inside the working area.
Do not smoke inside the working area.
During painting operations, or if there are some vapours in the air, do not switch on or off the lights
inside the working area.
Do not use any petrol engine inside the working area.
Some organic solvents or discharged toxic vapours can enter the eyes or the skin, be swallowed
or inhaled, provoking serious injuries.
When the air engine is running, keep the face away from the exhaust.
22
Содержание MSU-113 N
Страница 38: ...38 Plunger pump set type PP7131N...