23
5.8
Pressure release process
WARNING
1. Close the air supply to the pump by turning the pressure reducer adjustment anticlockwise down
to 0 bar.
2. Enable the safety catch of the multi spray gun trigger.
3. Make sure the recirculation pipe is not clogged, then gradually open the recirculation ball valve
and leave it open.
4. Hold the gun tightly and lean it against the metal vessel with the paint. Remove the safety catch of
the multi spray gun trigger and gently pull the trigger to release the pressure inside the multi spray
pipe and inside the gun.
5. Block the multi spray gun trigger once more by means of the safety catch.
6. If you believe the pressure has not been fully released by following the instructions provided in
point 4, loosen the gun nozzle carrier to gradually release the residual pressure, then loosen it
completely. Clean the fluid passage ducts.
Содержание MSU-113 N