21
5.5
Start
[ref. figure 2 page 17 and figure 3 page 18]
Before operation, start the pump by following the operations below:
1. Dip the suction hose (A) in the tank with the product to be pumped.
2. Open the recirculation valve (C) for paint recirculation.
3. Lift and gradually turn the pressure reducer knob (G). Adjust it to a pressure slightly higher than
2.0 bar, to enable the pump to release the air.
4. Close the two-way valve for paint recirculation (C) and release the air through the gun, as well.
5. Increase the pressure of the reducer connected to the pump, according to the desired working
pressure.
CAUTIONS
a) Use multi spray gun only.
b) When the paint level inside the tank decreases, the pump might suck some air. Increase the
level of paint.
c) Do not drag the pump by pulling it by the pipes.
d) Do not spray towards the eyes or towards other people
CAUTIONS: EMERGENCY STOP
WHEN THE PUMP MUST BE STOPPED BECAUSE OF ONE OF THE FOLLOWING REASONS:
a) The material never stops coming out of the gun
b) Fluid discharge through the connectors or the damaged pipe
- Close the BALL VALVE (E) (stop position)
WARNING
a) When assembling or removing the gun nozzle, always block the trigger safety catch.
b) Never remove the gun trigger safety catch
c) Never exceed the maximum working pressure (6.8 bar).
d) Always use a multi spray ANEST IWATA gun, which is provided with various safety devices.
e) During operation, never touch the moving parts. Before carrying out any maintenance opera-
tion, disconnect the air supply and discharge the residual pressure.
Содержание MSU-113 N