57
Item
Gas
Consumption (NET)
Hot Water Capacity
Capacity Range
Temperature Settings
1
2H
1
3P
25
°
C Rise
58
°
C Rise
32 L/min.
13 L/min.
3.5 - 32 L/min.
37 - 48, 50, 55, 60, 65, 70, 75, 80
°
C
Maximum Performance
Minimum Performance
Specification
Internal, Wall Hanging
Power Flue
Direct Ignition
2.0 bar
3.5 L/min.
61.5 cm(Height) x 46.4 cm(Width) x 24 cm(Depth)
29 kg
1.1 Litre
3/4"
3/4"
3/4"
230V AC (50Hz)
120W
Zincified Steel Plate/Polyester Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Pressure Relief Valve,
Lightning Protection Device (ZNR),
Electric Leakage Prevention Device, Overheat
Prevention Device, Freezing Prevention Device,
Fan Rotation Detector
Remote Controller, Anchoring Screws
Specifications
Performance
Item
Model Name
Type
Ignition
Minimum Pressure for Maximum flow
Minimum Flow Rate
Dimensions
Weight
Water Holding Capacity
Accessories
Installation
Air Supply/Exhaust
Connection Sizes
Power Supply
Materials
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Safety Devices
62.3 kW
62.3 kW
5.0 kW
5.0 kW
WH56 LWH56
112W
Freeze Prevention 115W
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water
pressure, water supply, piping conditions, and water temperature.
(L)WH42̲56(56̲57)̲E
05.9.26, 7:48 PM
Page 57
Adobe PageMaker 6.5J/PPC