![AND Explosion Protected Weighing Indicator AD-4403-FP ST Series Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/and/explosion-protected-weighing-indicator-ad-4403-fp-st-series/explosion-protected-weighing-indicator-ad-4403-fp-st-series_instruction-manual_2941315037.webp)
6-4
6-3 CALF-14=“1”
Weighing
Mode
(Normal batching in customer programmed control mode)
Output signal
Output condition
Zero band
Gross
weight
≤
Zero band
Full-flow Final
-
Optional preliminary
≤
Net weight
medium-flow Final
-
Preliminary
≤
Net weight
Dribble-flow Final
-
Free
fall
≤
Net weight
Over limit
Final +
Over limit
<
Net weight
Under limit
Net weight
< Final -
Under
limit
•
When an output condition is established, a relevant output terminal is turned on (power continuity with output COM).
•
An output terminal number can be selected with OUTF-01 through OUTF-08. See {Appendix C: Function List}
•
A set point signal output is turned off unconditionally when the operation mode is other than the normal mode.
Weighing process
*
Programming with a PLC (Programmable Logic Controller) is required for this weighing mode.
Sequence #
Process
1
•
The “Tare” signal is input.
•
The display shows “0”.
2
•
Gates G1 (full-flow), G2 (medium-flow), and G3 (dribble-flow) open.
•
The weight on the display is incremented, and reaches the weight of “Final –
Optional preliminary”.
•
The “Optional preliminary” output is turned ON.
•
Gate G1 closes.
3
•
The display shows the weight of “Final – Preliminary”.
•
The “Preliminary” output is turned ON.
•
Gate G2 closes.
4
•
The display shows the weight of “Final – Free fall”.
•
The “Final” output is turned ON.
•
Gate G3 closes.
•
Weighing completes at a stable display.
*
The display shows the final weight, indicating that hopper 2 has been filled to
that weight. Use the over limit/under limit setting to check whether the
weighing value is within limits.
5
•
Gate G4 (Discharging gate) opens to discharge and fill the container.
*
The use of the zero range setting can check if the ingredient has been
completely discharged.
Содержание Explosion Protected Weighing Indicator AD-4403-FP ST Series
Страница 22: ...2 7 Blank page...
Страница 36: ...6 3 Blank page...
Страница 38: ...6 5...
Страница 40: ...6 7...
Страница 53: ...6 20 Blank page...
Страница 73: ...8 18 Blank page...
Страница 83: ...Dimensions OP 20 Stand A 5...
Страница 85: ...A 7 Blank page...
Страница 87: ...B 2 Blank page...
Страница 105: ...Fig Apx D 02 Gravity map WMF D 2...
Страница 107: ...Form F Factory setting rSF 02 5 Command mode Address None rSF 09 0 Address 1 rSF 09 1 E 2...