![AND Explosion Protected Weighing Indicator AD-4403-FP ST Series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/and/explosion-protected-weighing-indicator-ad-4403-fp-st-series/explosion-protected-weighing-indicator-ad-4403-fp-st-series_instruction-manual_2941315020.webp)
2-5
2-3 Installing Conduit Fittings Option OP-10 - 14
Affix conduit fittings to the unit following the instructions below.
#
Parts Name
[ 1 ]
Lock nut
[ 2 ]
Gasket
[ 3 ]
Conduit fitting
[ 4 ]
Sealing tape
Procedures
1: Wind the [4] Sealing tape around the
[3] Conduit fitting.
2: Insert into the SERIAL hole through
the [2] Gasket.
3: Tighten it with the [1] Lock nut.
Содержание Explosion Protected Weighing Indicator AD-4403-FP ST Series
Страница 22: ...2 7 Blank page...
Страница 36: ...6 3 Blank page...
Страница 38: ...6 5...
Страница 40: ...6 7...
Страница 53: ...6 20 Blank page...
Страница 73: ...8 18 Blank page...
Страница 83: ...Dimensions OP 20 Stand A 5...
Страница 85: ...A 7 Blank page...
Страница 87: ...B 2 Blank page...
Страница 105: ...Fig Apx D 02 Gravity map WMF D 2...
Страница 107: ...Form F Factory setting rSF 02 5 Command mode Address None rSF 09 0 Address 1 rSF 09 1 E 2...