CLOCKING THE ADAV4601 USING THE 96-WAY CONNECTOR (BCLK1)
c) To clock the ADAV4601 using the BCLK1 from the 96 way connector, jumper 12 (J12) must be set to position 2-4.
Data from the 96 way connector in this mode can be synchronous or asynchronous, if there is data is from the SPDIF
connector this is asynchronous and can be handled using the SRC1. The appropriate register writes must be
performed to power up and enable the SRCs so as to ensure the correct operation of the device.
J12
Data from SPDIF,
asynchronous to MCLK
BCLK1
Data from 96 way,
asynchronous or
synchronous
J12
Data from SPDIF,
asynchronous to MCLK
BCLK1
Data from 96 way,
asynchronous or
synchronous
Figure 5. Clocking using the 96-way connector (BCLK1)
Once the board has been set up to use the 96-way connector the appropriate clock frequency must be
programmed in the ADAV4601. This can be done by writing directly to the initialization register in the ADAV4601
using SigmaStudio, please refer to the Appendix A – Detailed Register Descriptions for more details on register
settings.
Содержание ADAV4601
Страница 107: ...ADAV4601 System Design Document Confidential Information Rev 1 August 2009 Analog Devices Page 107 APPENDIX D SCHEMATICS...
Страница 108: ...ADAV4601 System Design Document Confidential Information Rev 1 August 2009 Analog Devices Page 108...
Страница 109: ...ADAV4601 System Design Document Confidential Information Rev 1 August 2009 Analog Devices Page 109...
Страница 110: ...ADAV4601 System Design Document Confidential Information Rev 1 August 2009 Analog Devices Page 110...
Страница 111: ...ADAV4601 System Design Document Confidential Information Rev 1 August 2009 Analog Devices Page 111...
Страница 112: ...ADAV4601 System Design Document Confidential Information Rev 1 August 2009 Analog Devices Page 112...